4OM-1322-006_w.pdf - 第180页

2-43 AKOEMT -ID T able 4B34 Error ID Error Name, Description, Cause, and Remedy 1307000 PCB T ransfer T ime Over PCB was not transfered from outp.conv . within specified time. (Cause 1) The PCB passage check sensor (B45) …

100%1 / 211
2-42 AKOEMT-ID
(13 PCB Transfer) Table 4B33
Error ID Error Name, Description, Cause, and Remedy
1301000 PCB Supply
PCB transfer signal was not offed after PCB detect.
1302000 PCB Supply
PCB transfer signal is off before PCB detect.
(Cause 1) Communication Error with Input Machine
(Remedy 1)
Check the PCB transfer signal from the input machine in the “Org./Signal
Info.” tab sheet. When the problem cannot be solved, contact our service
personnel for details.
1303000 Input Conveyor
Time Over
PCB from inp. machine was not received within specifi
ed time.
(Cause 1) The set value of the timer is too short.
(Cause 2) The conveyor speed is too slow.
(Cause 3) The PCB detection sensor (B41) is not working.
(Remedy 1) Set a larger parameter in the “Output Conveyor” text box of the “Timer Setting
(sec)” group box in the “Transfer Mode Set-up” tab sheet.
(Remedy 2) Turn up the variable resistor of the L conveyor speed control.
(Remedy 3) Check how the sensor is working in “DEVICE CHECK” window (submenu).
When the sensor is not working, it is required to adjust the sensor position or
replace the sensor with a new one. Contact our service personnel for details.
1304000 Output Conveyor
Time Over
PCB was not transfered to outp.conv
. within specified time.
(Cause 1) The set value of the timer is too short.
(Cause 2) Communication Error with Output Machine
(Remedy 1) Set a larger parameter in the “Output Conveyor” text box of the “Timer Setting
(sec)” group box in the “Transfer Mode Set-up” tab sheet.
(Remedy 2) Contact our service personnel for details.
1305000 PCB
Transfer
Time Over
PCB transfer from inp. conv. was not completed within specified time.
(Cause 1) The conveyor speed is too slow.
(Cause 2) The PCB detection sensor (B71) is not working.
(Remedy 1) Turn up the variable resistor of the L conveyor speed control.
(Remedy 2) Check how the sensor is working in “DEVICE CHECK” window (submenu).
When the sensor is not working, it is required to adjust the sensor position or
replace the sensor with a new one. Contact our service personnel for details.
1306000 PCB
Transfer
Time Over
PCB transfer to outp.conv. was not completed within specified time.
(Cause 1) The PCB arrival check sensor (B44) is not working.
(Remedy 1) Check how the sensor is working in “DEVICE CHECK” window (submenu).
When the sensor is not working, it is required to adjust the sensor position or
replace the sensor with a new one. Contact our service personnel for details.
0609-002
2.2 Troubleshooting after Error Display
2-43 AKOEMT-ID
Table 4B34
Error ID Error Name, Description, Cause, and Remedy
1307000 PCB Transfer
Time Over
PCB was not transfered from outp.conv. within specified time.
(Cause 1) The PCB passage check sensor (B45) is not set in the E/NR (Light Emitted and
Not Received) or the E/R (Light Emitted and Received) mode.
(Remedy 1) Check how the sensor is working in “DEVICE CHECK” window (submenu).
When the sensor is not working, it is required to adjust the sensor position or
replace the sensor with a new one. Contact our service personnel for details.
1308000 PCB Transfer
Time Over
PCB transfer to input conv. was not completed within specified time.
(Cause 1) The PCB detection sensor (B41) is not set in the E/NR (Light Emitted and Not
Received) or the E/R (Light Emitted and Received) mode.
(Cause 2) The conveyor speed is too slow.
(Remedy 1)
Check how the sensor is working in “DEVICE CHECK” window (submenu).
When the sensor is not working, it is required to adjust the sensor position or
replace the sensor with a new one. Contact our service personnel for details.
(Remedy 2) Turn up the variable resistor of the L conveyor speed control.
1309000 Input Conveyor Interlock
PCB Backup axis was up.
1310000 Output Conveyor Interlock
PCB Backup axis was up.
(Cause 1)
Dirt adheres to the backup axis near origin sensor and the optical beam is
shielded.
(Cause 2) The backup axis near origin sensor is defective.
(Cause 3) The backup axis driver is malfunctioning or an error has occurred during
communication with the host CPU.
(Remedy 1)
Wipe off the dirt on the sensor and zero the PCB backup axis again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine again.
After that, zero the PCB backup axis. If this operation does not reset the
machine to its normal condition, the driver may be defective. Contact our
service personnel for details.
1312000 PCB Transfer Interlock
Input Conveyor motor was running.
1313000
PCB Transfer Interlock
Output conveyor motor was running.
(Cause 1)
Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
0609-002
2.2 Troubleshooting after Error Display
2-44 AKOEMT-ID
Table 4B35
Error ID Error Name, Description, Cause, and Remedy
1314000 PCB Transfer Interlock
2 PCB was on table.
(Cause 1)
The overlapped PCB's were transferred.
(Cause 2) Two PCB's were transferred in succession.
(Cause 3) The overlapped PCB detection sensor (B6A) section is not adjusted correctly.
(Remedy 1) Remove the PCB’s and restart the operation.
(Remedy 2) Remove the PCB’s and restart the operation.
(Remedy 3) Contact our service personnel for details.
1315000 T
able Stopper Interlock
PEC Recog-X Axis was running.
1316000
Table Stopper Interlock
PEC Recog-Y
Axis was running.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1317000 T
able Stopper Interlock
PCB was took on table.
(Cause 1) The stopper was moved down when a PCB is still on the table. (during the
manual operation)
(Cause 2) The PCB check sensor (B69) is defective.
(Remedy 1) Remove the PCB and restart the operation.
(Remedy 2)
Check how the sensor is working in “DEVICE CHECK” window (submenu).
When the sensor is not working, it is required to replace the sensor with a new
one. Contact our service personnel for details.
1318000 Output Cnvr. Stopper Interlock
Output conveyor motor was running.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1319000
Output Cnvr
. Stopper Interlock
PCB was took on output conveyor.
(Cause 1)
A PCB is still on the output conveyor.
(Cause 2) The PCB arrival and passage check sensors (B44 and B45) are defective.
(Remedy 1) Remove the PCB and restart the operation.
(Remedy 2) Check how the sensors are working in “DEVICE CHECK” window (submenu).
When the sensors are not working, it is required to replace the sensors with
new ones. Contact our service personnel for details.
0609-002
2.2 Troubleshooting after Error Display