Safe-29 AKOE-ID Safety Precautions Switch Name Symbol Countermeasures [EMERGENCY STOP] Switch (Front) [EMERGENCY STOP] Switch (Rear) S10 S1 1 Pressing one of the [EMERGENCY STOP] switches cuts power to the following modu…

Safety Precautions
Safe-28
AKOE-ID
5. Safety-Related Functions
Safety Switches
When an error is detected in the machine, the safety switches are designed to stop the
dangerous moving mechanisms of the machine. Everything is processed on the machine
side (hardware) without using any software application on the computer side.
[EMERGENCY STOP] Switches
Press one of the [EMERGENCY STOP] switches to immediately stop the machine
in an emergency.
The machine stops and the power is turned off immediately.
[EMERGENCY STOP] Switch
[EMERGENCY STOP] Switch
Front View Rear View
0704-002

Safe-29
AKOE-ID
Safety Precautions
Switch Name Symbol Countermeasures
[EMERGENCY STOP] Switch
(Front)
[EMERGENCY STOP] Switch
(Rear)
S10
S1
1
Pressing one of the [EMERGENCY STOP]
switches cuts power to the following modules.
•
All power sources for loads are shut off.
The power supply to the mechanisms of all
motor shafts and 24-voltage loads in the
solenoid system (SOL and SV) is shut off.
Note:
The control power supply for the
control boards, switches, and lamps
is excluded.
0704-002

Safety Precautions
Safe-30
AKOE-ID
[Door Check] Switches
When the door is opened with the [OPERATION/SET UP] switch set to the
"OPERATION" side, the switch is activated and an error condition is indicated.
When the switch is set to the "SET UP" side, this switch is not activated.
S12
S13
S12
S14
S13
Top View
Front View Rear View
Switch Name Symbol Countermeasures
[Door Check] Switch S12
S13
S14
When the door is opened, the following measures
are taken.
•
All power sources for loads are shut off.
The power supply to the mechanisms of all
motor shafts and 24-voltage loads in the solenoid
system (SOL
and SV) is shut off.
Note:
The control power supply for the control
boards, switches, and lamps is excluded.