DECAN_S2_Trouble(Eng_Ver4.2).pdf - 第125页
1-103 System Messages of the MMI and Solutions $6021 Since a par t is picked u p b y the head spindle nozzle, i t is not possible to re turn the nozzle to the ANC. [EMER LEVEL] [Problem] A part is picked up by the no z…

1-102
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
$6015 The head does not have sufficient nozzles for performing cycle work. [EMER LEVEL]
[Problem]
The number of nozzles registered in the ANC is smaller than that of the nozzles
registered in the ‘Step’ dialog box.
[Solution]
Turn off the buzzer by pressing the “STOP” button.
Press the “RESET” button to change the operation mode to “IDLE”.
Register nozzles to fill the nozzle shortage in the ‘ANC Manager’ dialog box and
arrange them to the ANC.
$6020 Can't put, no nozzle in the head.
[Problem]
Nozzles actually do not exist at head when trying to put nozzles.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Nozzles actually do not exist at head when trying to put nozzles.
Nozzles actually do not exist at head when trying to put nozzles.
Although there is no nozzle actually mounted on the head, if it is set up to have been
mounted on the head in the dialog box of the ANC menu, check the ‘No real motion
(Manual)’ and perform ANC setup again by clicking the <Put all nozzle> button.

1-103
System Messages of the MMI and Solutions
$6021 Since a part is picked up by the head spindle nozzle, it is not possible to return the
nozzle to the ANC. [EMER LEVEL]
[Problem]
A part is picked up by the nozzle when returning the head spindle nozzle to the ANC.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Press the “RESET” button to change the operation mode to “IDLE”.
Check whether a part is picked up by the head spindle nozzle.
Select the ‘Device’ submenu of the ‘System Setup’ menu and select the ‘Nozzle’ item.
Then check the ‘Check Vacuum’ value in the ‘Nozzle’ dialog box.

1-104
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
Check if the supplied pneumatic pressure is as high as the set pressure (0.45 ~ 0.55
MPa) by the air pressure gauge through air panel on the front side of the machine.
1: Pressure Decrease (Counterclockwise)
2: Pressure increase (Clockwise)
$6030 Nozzle in the head. Can't put. [FREEZE LEVEL]
[Problem]
Following the nozzle ‘PUT’ operation, if the ANC hole center is not aligned, the
nozzle put operation is performed due to inadequate height setup, or the nozzle
actually mounted on the head, etc.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Press the “READY” button to supply power to the machine.
After clicking the ‘Fiducial Mark Detail…’ on the ANC dialog box, move to the
fiducial mark to check if the fiducial mark position is properly setup. If not, perform
teaching again. For details on teaching, please refer to “6.3 Fiducial Mark Setup” in
the “Administrator’s Guide”.