Advanced Chip Shooter DECAN S2 Troubleshooting Guide
Check if the supplied pneumatic pressure is as high as the set pressure (0.45 ~ 0.55
MPa) by the air pressure gauge through air panel on the front side of the machine.
1: Pressure Decrease (Counterclockwise)
2: Pressure increase (Clockwise)
$6030 Nozzle in the head. Can't put. [FREEZE LEVEL]
[Problem]
Following the nozzle ‘PUT’ operation, if the ANC hole center is not aligned, the
nozzle put operation is performed due to inadequate height setup, or the nozzle
actually mounted on the head, etc.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Press the “READY” button to supply power to the machine.
After clicking the ‘Fiducial Mark Detail…’ on the ANC dialog box, move to the
fiducial mark to check if the fiducial mark position is properly setup. If not, perform
teaching again. For details on teaching, please refer to “6.3 Fiducial Mark Setup in
the “Administrator’s Guide”.
1-105
System Messages of the MMI and Solutions
First, execute the “Position” dialog box by clicking the button. After clicking
the ‘Hole Position Detail …’ in the ANC menu, select the error occurred ANC hole to
verify if the coordinates of the hole are correct and check if the selected device to be
moved is selected as “FidCam”. Then check if the hole center matches with the setup
position by clicking the <Move> button to move to the corresponding ANC hole.
Also, check if the set Z value of the ANC hole coordinate is accurate by moving down
the Z-axis manually using the teaching box.
1-106
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
Check if the shutter operates correctly by clicking ‘Shutter On/Off’ on the ANC dialog
box.