DECAN_S2_Trouble(Eng_Ver4.2).pdf - 第149页
1-127 System Messages of the MMI and Solutions The mirror is contamina ted with foreign matter . he nozzle is conta minated with foreign matter or its coating was peeled off. Component data and lig hting is inadequ…

1-126
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
[Solution]
Perform [Solution[Solution]] in $a635.
$a641 There is a bright pixel outside the first(left side) lead of upper lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.
The mirror is contaminated with foreign matter.
The nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635.
$a642 There is bright pixel at the first(upper side) lead of left lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.
The mirror is contaminated with foreign matter.
The nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635.
$a643 There is bright pixel outside of the first(left side) lead of lower lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.
The mirror is contaminated with foreign matter.
he nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635..
$a644 There is bright pixel outside of the first(left side) lead of lower lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.

1-127
System Messages of the MMI and Solutions
The mirror is contaminated with foreign matter.
he nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635.
$a645 Boundary at the first(left side) lead of upper lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of the component is actually defective.
False recognition of foreign matter as lead.
The component data and lighting setup is inadequate.
[Solution]
The component data and lighting setup is inadequate.
Perform [Solution] in $a635.
$a646 Boundary at the first(upper side) lead of left side lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of the component is defective.
False recognition of foreign matter as lead.
False recognition of foreign matter as lead.
[Solution]
Check if the lead is defective.
Perform [Solution] in $a635.
$a647 Boundary at the first(left side) lead of the lower lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of component is defective.
False recognition of foreign matter as lead.
Component data and lighting setup is inadequate.
[Solution]
Check if the lead is defective.
Perform [Solution] in $a635.

1-128
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
$a648 Boundary at the first(upper side) lead of right side lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of the component is defective.
False recognition of foreign matter as lead.
The component data and lighting setup is inadequate.
[Solution]
Check if the lead is defective.
Perform [Solution] in $a635.
$a649 First(left side) lead of upper lead group is a not straight line.
[Problem]
Recognized the component lead is seriously damaged.
The component lead is defective.
The component lead does not look uniform.
[Solution]
Check if the component lead is actually defective.
If leads of a component do not appear uniform, perform recognition by selecting the
‘Fix Camera’ as a camera for recognizing components.
$a64a First(upper side) lead of left side lead group is not straight.
[Problem]
The component lead is recognized to have been damaged seriously.
The component lead is defective.
The component lead does not look uniform.
[Solution]
Check if the component lead is defective.
If leads of a component do not appear uniform, perform recognition by selecting the
‘Fix Camera’ as a camera for recognizing components.
$a64b First(left side) lead of lower lead group is not straight.
[Problem]
The component lead is recognized to have been damaged seriously.
The component lead is defective.
The component lead does not look uniform.
[Solution]