DECAN_S2_Trouble(Eng_Ver4.2).pdf - 第169页
1-147 System Messages of the MMI and Solutions $ab1e An error occurred while executing the int ernal function. [Problem] An error occurr ed during component recognition. [Solution] T urn of f power to the machine in …

1-146
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
$ab17 Distance between upper leads deviated from the reference value.
[Problem]
Deviated from the reference value because the upper leads were bent.
[Solution]
Check if the leads of the component are bent.
$ab18 Distance between the lower leads deviated from the reference value.
[Problem]
Deviated from the reference value because the lower leads were bent.
[Solution]
Check if the leads of the component are bent.
$ab19 Angle of the component is deviated from the reference value.
[Problem]
The angle of the component has been rotated too much when picking up the
component.
[Solution]
Perform [Solution] in $aa0b.
$ab1a Angle between the upper leads deviated from the reference value.
[Problem]
Deviated from the reference value because the upper leads ware bent.
[Solution]
Check if the leads of the component are bent.
$ab1b Angle between the lower leads deviated from the reference value.
[Problem]
Deviated from the reference distance because the lower leads were bent.
[Solution]
Check if the leads of the component re bent.
$ab1d An incorrect algorithm number has been input in the internal function.
[Problem]
An incorrect result has been received from the VME.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.

1-147
System Messages of the MMI and Solutions
$ab1e An error occurred while executing the internal function.
[Problem]
An error occurred during component recognition.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ab1f Internal function Error(TrCenterCorrection).
[Problem]
An error occurred during component recognition.
[Solution]
If a component is not picked up, assign the component pickup position again at the
PCB edit feeder of the MMI. Through the SMVision window, check the pickup
position of the corresponding component in “Feeder” of the “PCB Edit” menu.
Check if the lead of the picked up component is bent.
Select the error occurred component in “Part” of the “PCB Edit” menu and verify in
the “Profile Editor” if lead information (lead width, lead pitch) is correctly input.
$ab20 Internal function Error(TrCenterCorrection).
[Problem]
An error occurred during component recognition.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ab21 Total number of leads is less than two.
[Problem]
The sum of the upper leads and lower leads is less than two.
Recognition is impossible when the sum of leads is less than two.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu, check the
“Lead Num” on the “Profile Editor”, and input the accurate number of leads.
$ab22 Total number of leads is too many.
[Problem]
Total number of upper leads and lower leads is more than 30.
Recognition is impossible when the sum of leads is more than 30.

1-148
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu, check the
“Lead Num” on the “Profile Editor”, and input the accurate number of leads.
$ab23 Number of leads is a minus value.
[Problem]
Received incorrect value from the VME.
The lead number is inputted in a minus value.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu, check the
“Lead Num” on the “Profile Editor”, and input the accurate number of leads.
$ab24 Undefined algorithm.
[Problem]
An incorrect result has been received from the VME.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ab25 Undefined angle.
[Problem]
An incorrect result has been received from the VME.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ab26 Error occurred while inspecting leads.
[Problem]
Did not pickup the component.
Lead of the component is bent too much.
Incorrect input of lead information.
[Solution]
Perform [Solution] in $aa1f.
$ab27 Error occurred while inspecting leads.
[Problem]
The component was not picked up.