1-4 Advanced Chip Shooter DECAN S2 T roubleshooting Guide Incorrect feeder base adj ustment E0127 Part wear/distortion in the fee der E0128 S procket, ratchet, etc., are cont aminated with foreign materials. E0129 Incorr…

1-3
System Messages of the MMI and Solutions
Normal Part Supply
A pickup error occurred
Cause Description Remarks
Low vacuum
pressure / delayed
vacuum creation
A component of the head’s pneumatic system
is defective
E0100
Vacuum air line is contaminated E0101
Low vacuum pressure due to an oil leak into
the vacuum generator
E0102
Defective contact of the head vacuum solenoid
cable connector
E0102
Defective assembly of the solenoid valve
connector in front of the vacuum generator
E0104
Defective head I/O board E0105
Defective vacuum sensor board E0106
Air leak
s from (Rotary joint, Coil Tube or
Fittings, Vacuum Sensor Board
E0107
Main pneumatic pressure setup error E0108
Blow setup error E0109
Incorrect Vac Delay setup E0110
Pickup position
Error
Incorrect XY coordinates of the pickup point
due to ball spline deformation
E0120
Incorrect setup of the XY coordinates of the
pickup point (Tape, Vibration, Tray Feeder)
E0121
Incorrect tape guide position E0122
Splicing err
or E0123
Incorrect Y position for pickup when installing
tape
E0124
Incorrectly set X coordinate for pickup when
installing tape
E0125
Incorrect pickup position adjustment E0126

1-4
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
Incorrect feeder base adjustment E0127
Part wear/distortion in the feeder E0128
Sprocket, ratchet, etc., are contaminated with
foreign materials.
E0129
Incorrect setup of the part supply position
according to tray shape and part
characteristics
E0130
Incorrect setup of Z and Pick Z values E0131
Foreign materials in the feeder base slot and
clamp
E0132
Incorr
ect Z offset setup E0133
Z Offset change E0134
Problem with
Nozzle
Standard nozzle not used E0140
Damaged nozzle tip, abnormal nozzle spring
tension
E0141
Insufficient nozzle maintenance E0142
Use of nozzle unsuitable for the part E0143
A number of odd
shaped materials
have dropped
Vacuum check setup error E0150
A part dump error
occurred.
Parts are not dumped properly due to incorrect
blow pressure setup
E0160
Cause Description Remarks

1-5
System Messages of the MMI and Solutions
When parts are picked up properly - Part recognition error [Refer to Section
1.2.1.2]
Cause Description Remarks
Failed to output the
images taken by the
camera
.Defective fly camera or fix camera
.Defective fly camera I/F cable or defective
stage CAM 1 and 2 cables and connections
.Defective Fly Camera PW Sync Exit Cable
and connection
.Defective vision board
.Defective vision I/F board
.Defective camera I/O board (total
destruction of internal chips by fire)
.Defective power supply
.Defective vision board I
F cable and
connection
E0200
Damaged image from
the camera
Unclear image from the
camera
.Defective Fly Cam Sig Ext cable or Fix Cam
signal cable and connection
.Defective camera focus
.Contaminated camera lens and foreign
material on the lens
.Camera dip switch setup error
E0201
Vision processing
timeout /
Failed to recognize the
vision board
.Defective Vision board connection
.Defective SBC
.Defective vision
board
.Defective backplane board
.Damaged vision board driver file due to
infection by virus
E0202
Damage to the mirror .Scratch to the mirror
.Damaged mirror
.Mirror contaminated with foreign material
E0203
Part data registration
error
.Part recognition data registration error
.Recognition parameter setup error
.Illumination setup error
E0204
Defective part The part size is different from that of the
recogniti
on data of the registered part due to
a defective part
E0205