DECAN_S2_Trouble(Eng_Ver4.2).pdf - 第53页

1-31 System Messages of the MMI and Solutions  After replacing the sol enoid valve, set the blow pressure level. E0324 A part a dheres to the nozzle since the blow pressure becomes low d ue to a c logged spindle [Cause]…

100%1 / 200
1-30
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
When the regulator pressure is 0.1Mpa, adjust the needle valve of the manifold so
that the blow set value becomes -40 ~ -60 mmHg.
E0310 A PCB warps up and down
[Cause]
The placement height has deviated as the PCB has warped downwards.
The part bounces out since the PCB is warped upward.
[Measures]
Check the flatness of the PCB using a 'ruler' with the PCB fixed. Replace the PCB
causing the problem.
E0320 A part adheres to the nozzle since the blow pressure is excessively low
[Cause]
Blow pressure becomes excessively low due to incorrect setup of the blow solenoid
valve
[Measures]
Control the blow solenoid valve so that the lower limit value of blow becomes -
50mmHg when the regulator pressure is 0.06Mpa. Regarding the method to control
the solenoid valve, contact our designated C/S company or local agent.
E0321 A part drops since the vacuum pressure is low due to a fouled vacuum filter
[Cause]
The generation of blow and vacuum pressure is delayed due to a fouled filter
[Measures]
Check the filter for discoloration. If it has a problem, replace the vacuum filter. (The
vacuum filter is a consumable part, replace it every 6 months)
E0322 Air leaks from the vacuum filter since its case was assembled incorrectly or damaged
[Cause]
Filter case was damaged
[Measures]
Replace the head vacuum filter case.
E0323 A part adheres to the nozzle since the blow pressure becomes low due to a defective
solenoid valve
[Cause]
Defective solenoid valve
[Measures]
1-31
System Messages of the MMI and Solutions
After replacing the solenoid valve, set the blow pressure level.
E0324 A part adheres to the nozzle since the blow pressure becomes low due to a clogged
spindle
[Cause]
Clogged spindle
[Measures]
Clean the spindle periodically referring to the Maintenance Handbook.
Open the 'Pneumatic Pressure Diagnosis' dialog box of the MMI and insert the CN040
nozzle into the nozzle holder. Then turn on the vacuum system. The normal head
vacuum level is 600~700mmHg with the nozzle end covered with a hand. (The nozzle
and vacuum level differ by machine.)
E0325 A part adheres to the nozzle since the blow pressure becomes low due to an air leak
from therotary joint
[Cause]
Air leaks from the rotary joint
[Measures]
Replace the rotary joint.
E0326 The pickup section of the LED part consists of adhesive material
[Cause]
Since the pickup section of the LED part is treated with silicon, it is sticky
[Measures]
Select the nozzle suitable to the LED and perform a dump test. If the problem occurs
continuously, contact our designated C/S company or local agent.
E0327 A part adheres to the nozzle since the blow pressure becomes low with the oil entering
the vacuum generator
[Cause]
Fouled vacuum generator filter
[Measures]
Contact our designated C/S company or local agent. (Replace the vacuum generator)
E0328 A part adheres to the nozzle since static electricity is generated between the nozzle and
part
[Cause]
Static electricity was generated between the nozzle and part
1-32
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
[Measures]
After eliminating the static electricity with an ionizer, perform the work using a
genuine nozzle.
E0329 A part adheres to adhesive foreign material adhering to the nozzle tip
[Cause]
The nozzle tip is contaminated with solder or foreign materials
[Measures]
Clean the nozzle periodically referring to the Maintenance Handbook.
E0340 Standard nozzle is not used
[Cause]
Standard nozzle is not used
[Measures]
Use the standard nozzle supplied by Hanwha Precision Machinery Co., Ltd.. The
'HANWHA' logo is printed on the side of the nozzle supplied by Hanwha Precision
Machinery Co., Ltd..
E0341 The nozzle not suitable to the part was used
[Cause]
A nozzle suitable for the part is not used
[Measures]
Change the nozzle with the one suitable for the corresponding work referring to the
Operation Handbook.
E0350 Failed to detect a pickup error due to a defective vacuum sensor board
[Cause]
The vacuum sensor board is defective
[Measures]
Contact our designated C/S company or local agent. (Replace the sensor board)
E0351 Defective nozzle check sensor operation (PIP part)
[Cause]
The nozzle check sensor does not operate due to interference with the light source
[Measures]
Check whether the nozzle check sensor operates properly. If the problem occurs
continuously, contact our designated C/S company or local agent.