Advanced Chip Shooter DECAN S2 Troubleshooting Guide
[Measures]
After eliminating the static electricity with an ionizer, perform the work using a
genuine nozzle.
E0329 A part adheres to adhesive foreign material adhering to the nozzle tip
[Cause]
The nozzle tip is contaminated with solder or foreign materials
[Measures]
Clean the nozzle periodically referring to the Maintenance Handbook.
E0340 Standard nozzle is not used
[Cause]
Standard nozzle is not used
[Measures]
Use the standard nozzle supplied by Hanwha Precision Machinery Co., Ltd.. The
'HANWHA' logo is printed on the side of the nozzle supplied by Hanwha Precision
Machinery Co., Ltd..
E0341 The nozzle not suitable to the part was used
[Cause]
A nozzle suitable for the part is not used
[Measures]
Change the nozzle with the one suitable for the corresponding work referring to the
Operation Handbook.
E0350 Failed to detect a pickup error due to a defective vacuum sensor board
[Cause]
The vacuum sensor board is defective
[Measures]
Contact our designated C/S company or local agent. (Replace the sensor board)
E0351 Defective nozzle check sensor operation (PIP part)
[Cause]
The nozzle check sensor does not operate due to interference with the light source
[Measures]
Check whether the nozzle check sensor operates properly. If the problem occurs
continuously, contact our designated C/S company or local agent.
1-33
System Messages of the MMI and Solutions
E0360 The PCB was bypassed without being worked on due to the defective PCB detection
sensor
[Cause]
The PCB sensor is defective.
[Measures]
Contact our designated C/S company or local agent. (Replace the sensor)
1.2.2.2. Abnormal Placement Error
E0400 The XY coordinates of the corresponding spindle center become incorrect due to a
deformed ball spline
[Cause]
The ball spline is warped
[Measures]
Contact our designated C/S company or local agent. (Replace the ball spline)
E0401 Incorrect common data setup
[Cause]
1) Incorrect setup of vacuum/blow delay time
2) Incorrect part transfer speed setup
[Measures]
1) Set the delay time suitable for the part to be placed while changing the vacuum/blow
delay time little by little.
2) Set the speed suitable for the part to be placed while changing the part transfer speed
little by little.
E0402 The Z-axis driving system was not connected properly
[Cause]
Defective motor or belt connection
[Measures]
Contact our designated C/S company or local agent. (Check the driving motor and belt
for any defect)
E0403 The Z-axis motor driver does not operate properly
[Cause]
Incorrect gain or properties of the motor were inputted.
[Measures]
1-34
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
Check the AMP parameter.
Check whether noise is heard while the machine is stopped, JOG and operation. If so,
contact our designated C/S company or local agent. (Download the corresponding
parameters or change specific parameters again).
E0404 The Z axis LM guide is defective
[Cause]
The LM Guide is defective
[Measures]
Contact our designated C/S company or local agent. (Replace the ball spline)
E0410 Gantry offset occurred since calibration has not been performed for a long period of
time
[Cause]
Calibration has not been performed for a long period of time. (Condition change
according to the site environment)
[Measures]
Perform the common XY calibration referring to the Administrator's Guide.
E0411 After a certain period of time, XY coordinate distortion occurred in the working area
of a certain gantry.
[Cause]
Gantry mapping was performed incorrectly due to a defective fiducial mark position
for the temperature mapping of a certain gantry.
[Measures]
Check whether the fiducial mark position for temperature mapping is correct and
perform temperature mapping again.
E0412 Incorrect X and Y limit setup
[Cause]
Incorrect X and Y limit setup
[Measures]
Perform the axis calibration referring to the Administrator's Guide.
E0413 The offsets of the front/rear fiducial cameras were changed
[Cause]
The offsets of the front/rear fiducial cameras occurred
[Measures]