DECAN_S2_Trouble(Eng_Ver4.2).pdf - 第86页

1-64 Advanced Chip Shooter DECAN S2 T roubleshooting Guide  If the problem rema ins unsolved, contact our designated C/S c ompany or local agent. 1.4.3. Axis related error [$1000~$1fff] $1000 -H/W Limit is sensed at the…

100%1 / 200
1-63
System Messages of the MMI and Solutions
$0120 The feeder exchange button was pressed.. [NORMAL LEVEL]
$0805 Cannot operate the feeder since the Z-axis position is not safe . [EMER LEVEL]
[Problem]
The Z-axis of all heads is not at the safe height before operating the feeders (including
tray feeder).
[Solution]
When the Z-axis of some heads is lowered, perform homing of the Z-axis of the
corresponding head and attempt the planned operation.
When feeders were operated after EMG occurred without performing the homing,
perform the homing first and then attempt the planned operation.
If the problem remains unsolved, contact our designated C/S company or local agent.
$0915 The Y Interference detection sensor detected the approach of other gantries. [EMER
LEVEL]
[Problem]
The Y interference detection sensor detected the approach of other gantries.
[Solution]
The Y interference detection sensor detected the approach of other gantries.
Check if the two approaching gantries were detected by the interference sensor.
Check the operation status of the proximity sensor.
Press the Stop button and Reset button in order to release the error state of the
machine.
Perform homing of the entire machine to check if the homing is performed properly.
Check the connection state of the servo system (axis boards, motor boards).
The problem remaining unsolved may cause serious problems including collision of
the gantry with an internal frame, etc. Therefore, stop the machine immediately and
contact our designated C/S company or local agent
$0950 The teaching box is disabled at the front side. [WARNING LEVEL]
$0951 The teaching box is disabled at the rear side. [WARNING LEVEL]
$0952 The teaching box is connected to both front and rear sides . [WARNING LEVEL]
[Problem]
The teaching box is connected to both operation panels.
[Solution]
Remove the teaching box at one side for normal operation.
It is presumed that an error occurred in the distribution board of the operation panel.
Check the operation state.
1-64
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
If the problem remains unsolved, contact our designated C/S company or local agent.
1.4.3. Axis related error [$1000~$1fff]
$1000 -H/W Limit is sensed at the corresponding axis. [EMER LEVEL]
[Problem]
$1000- H/W Limit is sensed at the corresponding axis. [EMER LEVEL]
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Move the head to a position that can't be sensed by the H/W limit sensor..
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Supply power to the motor of the machine by pressing the “READY” button.
Select the submenu for calibration in the system setup menu and then click the <Axis
Home Calibration> button. And find the limit again by clicking the <X-Y Axis Limit
Automatic Searching…> button.
$1001 +H/W Limit is sensed at the corresponding axis. [EMER LEVEL]
[Problem]
The H/W limit sensor in + direction is sensed at the specified axis.
[Solution]
Take measures same as those against the error code "$1000”.
$1002 Alarm is sensed at the corresponding axis. [EMER LEVEL]
[Problem]
In the case of an axis, excessive pressing can cause this.
A motor error occurred at the specified axis.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Check the operation of the sensor and the actuator corresponding axis.(Motor, Z/R
Sensor, Z-Axis Offset so on)
If any problem occurs, contact the C/S company designated by Hanwha Precision
Machinery Co., Ltd. or the local agent.
1.4.4. Conveyor related error [$3000~$3fff]
$3000 PCB is in the conveyor area. [FREEZE LEVEL]
[Problem]
1-65
System Messages of the MMI and Solutions
A PCB is on the conveyor when the conveyor width is to be adjusted
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Press the “RESET” button to change the operation mode to “IDLE”.
Remove the PCB from the conveyor.
Remove the PCB from the conveyor.
Warning Adjusting the sensor or correcting an error while the
equipment is ready could result in personal injury. Be sure
to adjust the sensor or correct an error in the stop status
(idle mode) after canceling the ready status.
$3042 Check the state of the backup table. [EMER LEVEL]
[Problem]
When the backup table does not move up or down due to mechanical interference.
When pneumatic pressure is not supplied to the cylinder of the backup table properly.
A problem occurred in the position and wiring of the sensor related to the upward
movement of the backup table.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
If there is mechanical interference related to the up/down movement of the backup
table, remove it.
Check if pneumatic pressure is supplied normally (0.45-0.55Mpa) from the front