1-74 Advanced Chip Shooter DECAN S2 T roubleshooting Guide  Check the range wi thin which the shuttle can be moved and select the submenu for calibration in the system setup menu and then click the <Axis Ho me Calibr…

100%1 / 200
1-73
System Messages of the MMI and Solutions
Make the width of all conveyor stations identical.
$306a Timeout occurred while changing conveyor width. [EMER LEVEL]
[Problem]
The conveyor width failed to be adjusted as designated within designated time while
changing conveyor width.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Check if there is any mechanical interference while changing conveyor width.
Check the operation state of the step control board and PB driver related to the width
adjustment of the corresponding conveyor
$306b Timeout occurred while the conveyor is homed. [EMER LEVEL]
[Problem]
The conveyor width failed to be adjusted as designated within designated time while
homing the rail axis.
[Solution]
Take measures same as those against the error code "$306a”.
$306c An error occurred to the shuttle controller. [EMER LEVEL]
[Problem]
The machine operated incorrectly to the command related to the shuttle.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Check if there is mechanical interference related to the shuttle movement.
Check the operation state of the step control board and PB driver related to the shuttle
movement.
$306e The shuttle moved out of its movement range. [EMER LEVEL]
[Problem]
The shuttle moved out of its mechanical movement range..
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Supply power to the motor of the machine by pressing the “READY” button.
1-74
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
Check the range within which the shuttle can be moved and select the submenu for
calibration in the system setup menu and then click the <Axis Home Calibration>
button. Next select the corresponding shuttle axis and perform the home calibration
before restart.
$3073 Attempt was made to move the shuttle while the shuttle is being moved [EMER
LEVEL]
$3074 The shuttle needs to be homed. [EMER LEVEL]
[Problem]
When operating the shuttle that was not homed.
[Solution]
Take measures same as those against the error code “$3061”.
$3077 The shuttle movement was not completed. [EMER LEVEL]
[Problem]
Timeout occurred before the shuttle movement was completed.
[Solution]
Take measures same as those against the error code “$306c”.
$307b Timeout occurred when moving the shuttle. [EMER LEVEL]
[Problem]
Timeout occurred while moving the shuttle.
[Solution]
Take measures same as those against the error code “$306c”.
$307c Timeout occurred when moving the shuttle. [EMER LEVEL]
[Problem]
Timeout occurred while moving the shuttle.
[Solution]
Take measures same as those against the error code “$306c”.
$3080 There is an unknown board in the station. [EMER LEVEL]
[Problem]
There is a station in which the PCB with no transfer history was detected.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
1-75
System Messages of the MMI and Solutions
Match the conditions related to the corresponding station of the actual machine with
the MMI data.
Remove the corresponding PCB or create the history using the ‘New’ command.
$3083 A board was detected in the station. Remove the board first. [EMER LEVEL]
[Problem]
There is a station in which the PCB with no transfer history was detected.
[Solution]
Take measures same as those against the error code “$3080”.
$3086 Cannot disable the rail use since there is a board in the station. [EMER LEVEL]
[Problem]
A PCB exists in the corresponding station when disabling the rail.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
After removing the corresponding PCB, click the <Delete> button in the ‘Conveyor
Utilities’ dialog box of the MMI to delete the corresponding PCB information and
then disable the corresponding station.
$308c Scale calibration of the gantry %d fiducial camera is not performed. [FREEZE
LEVEL]
[Problem]
While finding the fiducial on the rail to check the width of the conveyor, scale
calibration of the fiducial camera finding the rail fiducial has not been performed.
[Solution]
Perform scale calibration of the fiducial camera of the corresponding gantry in the
‘Calib’ submenu of the ‘System Setup’ menu.
Since the scale calibration of the fiducial camera is basic for all calibrations, perform
calibration of the fiducial camera first.
$308d Failed to find the fiducial on the conveyor rail. [FREEZE LEVEL]
[Cause]
Failed to find the fiducial on the conveyor rail while finding the fiducial to check the
conveyor width.
The fiducial installed on the conveyor rail is not clean.
The corresponding fiducial is dirty or parts have fallen on the fiducial.
The light for the camera is too bright or too dark.