DECAN_S2_Trouble(Eng_Ver4.2).pdf - 第97页
1-75 System Messages of the MMI and Solutions Match the condition s related to the corresponding station of the act ual machine with the MMI data . Remove the c orresponding PCB or create the history using the ‘Ne w’…

1-74
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
Check the range within which the shuttle can be moved and select the submenu for
calibration in the system setup menu and then click the <Axis Home Calibration>
button. Next select the corresponding shuttle axis and perform the home calibration
before restart.
$3073 Attempt was made to move the shuttle while the shuttle is being moved [EMER
LEVEL]
$3074 The shuttle needs to be homed. [EMER LEVEL]
[Problem]
When operating the shuttle that was not homed.
[Solution]
Take measures same as those against the error code “$3061”.
$3077 The shuttle movement was not completed. [EMER LEVEL]
[Problem]
Timeout occurred before the shuttle movement was completed.
[Solution]
Take measures same as those against the error code “$306c”.
$307b Timeout occurred when moving the shuttle. [EMER LEVEL]
[Problem]
Timeout occurred while moving the shuttle.
[Solution]
Take measures same as those against the error code “$306c”.
$307c Timeout occurred when moving the shuttle. [EMER LEVEL]
[Problem]
Timeout occurred while moving the shuttle.
[Solution]
Take measures same as those against the error code “$306c”.
$3080 There is an unknown board in the station. [EMER LEVEL]
[Problem]
There is a station in which the PCB with no transfer history was detected.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.

1-75
System Messages of the MMI and Solutions
Match the conditions related to the corresponding station of the actual machine with
the MMI data.
Remove the corresponding PCB or create the history using the ‘New’ command.
$3083 A board was detected in the station. Remove the board first. [EMER LEVEL]
[Problem]
There is a station in which the PCB with no transfer history was detected.
[Solution]
Take measures same as those against the error code “$3080”.
$3086 Cannot disable the rail use since there is a board in the station. [EMER LEVEL]
[Problem]
A PCB exists in the corresponding station when disabling the rail.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
After removing the corresponding PCB, click the <Delete> button in the ‘Conveyor
Utilities’ dialog box of the MMI to delete the corresponding PCB information and
then disable the corresponding station.
$308c Scale calibration of the gantry %d fiducial camera is not performed. [FREEZE
LEVEL]
[Problem]
While finding the fiducial on the rail to check the width of the conveyor, scale
calibration of the fiducial camera finding the rail fiducial has not been performed.
[Solution]
Perform scale calibration of the fiducial camera of the corresponding gantry in the
‘Calib’ submenu of the ‘System Setup’ menu.
Since the scale calibration of the fiducial camera is basic for all calibrations, perform
calibration of the fiducial camera first.
$308d Failed to find the fiducial on the conveyor rail. [FREEZE LEVEL]
[Cause]
Failed to find the fiducial on the conveyor rail while finding the fiducial to check the
conveyor width.
The fiducial installed on the conveyor rail is not clean.
The corresponding fiducial is dirty or parts have fallen on the fiducial.
The light for the camera is too bright or too dark.

1-76
Advanced Chip Shooter DECAN S2 Troubleshooting Guide
Cannot find the corresponding fiducial position since the conveyor width has been
changed with the power supply turned off.
The gantry cannot move to the fiducial position since the position of the corresponding
fiducial is selected incorrectly.
This problem may be caused by an error of another system or by the vision itself.
[Measures]
When the fiducial camera fails to recognize the fiducial even though it is above the
fiducial, clean the fiducial at the center of the work station of the conveyor.
If the fiducial camera is not above the fiducial, remove the backup pin and take the
following actions.
If the ‘Rail Fiducial’ is enabled, click the button to perform homing.
If the problem occurs continuously, contact our designated C/S or local agent.
$308f An unknown error occurred in the station. [EMER LEVEL]
[Problem]
PCB was jammed while moving the PCB.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Check if there is mechanical interference that obstructs the flow of the corresponding
PCB.
Move the PCB to which a problem occurred manually and click the <Delete> button in
the ‘Conveyor Utilities’ dialog box of the MMI to delete the corresponding PCB
information.
$3091 The board sensor did not arrive at the inlet sensor.. [EMER LEVEL]
[Problem]
The PCB did not arrive normally before timeout from the machine at the previous
stage or previous station.
The PCB did not arrive normally before timeout from the machine at the previous
stage or previous station.
The belt of the corresponding station is not driven.
The PCB is not transferred due to mechanical interference.
The corresponding sensor operated incorrectly.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.