ASM-X-Spec-SX12V2-EN-DMS - 第12页
12 Modular machine concept SIPLACE SX1/SX2 Example of SIPLACE SX1 with WPC5/WPC6 PLEASE NOTE: For all po ssible head config- urations pleas e refer to section Mach ine Per- formance SIPLACE SX1/SX2 from page 13. COT 30 O…

11
Modular machine concept SIPLACE SX1/SX2
Example of SIPLACE SX2
PLEASE NOTE: For all possible head config-
urations please refer to section Machine Per-
formance SIPLACE SX1/SX2 from page 13.
COT 60 In Component trolley with 60
tracks in the inner position
COT 60 Out Component trolley with 60
tracks in the outer position
Head Placement head in acc.
with head configuration
NC Nozzle changer in acc.
with head configuration
G1 Gantry 1
G2 Gantry 2
PA Placement area

12
Modular machine concept SIPLACE SX1/SX2
Example of SIPLACE SX1 with WPC5/WPC6
PLEASE NOTE: For all possible head config-
urations please refer to section Machine Per-
formance SIPLACE SX1/SX2 from page 13.
COT 30 Out Component trolley with 30
tracks in the outer position
COT 60 In Component trolley with 60
tracks in the inner position
WPC Waffle Pack Changer,
type
5 or type 6
Head Placement head in acc.
with head configuration
NC Nozzle changer in acc.
with head configuration
IC Stationary camera
FC Flip chip camera
G1 Gantry 1
PA Placement area

13
Machine Performance SIPLACE SX1/SX2
Placement head types SIPLACE SpeedStar (C&P20)
SIPLACE MultiStar (CPP)
SIPLACE TwinStar (TH)
Placement performance
The placement performance is influenced by the different head combinations and head positions, plus the con-
veyor configurations. Individual options and customized applications also influence the placement performance.
On request, SIPLACE can calculate the actual performance of your product on your machine configuration.
IPC value [comp./h]
In line with the vendor-neutral conditions of the IPC 9850 standard published by the Association of Connecting
Electronics Industries.
SIPLACE Benchmark value [comp./h]
The SIPLACE benchmark value is measured during the machine acceptance tests. It corresponds to the condi-
tions specified
in the SIPLACE scope of service and supply.
Theoretical maximum output value [comp./h]
The theoretical maximum output value is calculated from the most favorable conditions for each machine type
and setting, and corresponds to the theoretical conditions normally used in the industry.
SIPLACE SX2 placement
machine
Placement area IPC value Benchmark value Theoretical value
C&P20 / C&P20 48,000 60,000 67,750
CPP / CPP
a
a) MultiStar CPP: low installation position
38,000 46,000 56,000
CPP
b
/ TH
b) MultiStar CPP: high installation position
23,100 27,000 31,000
TH / TH 10,200 11,000 13,000
SIPLACE SX1 placement
machine
Placement area IPC value Benchmark value Theoretical value
C&P20 24,000 30,000 33,875
CPP
a
19,000 23,000 28,000
TH 5,100 5,500 6,500