00192791-02 - 第43页
User Manual 2 Ceramic Substrate Centering Unit Software Version S R.502.xx 01/01 Issue 2.3 Mechanical Ceramic Substrate Centering 43 DANGER Only th e line eng ineer is p ermitted to perfor m the foll owing wor k. The saf…

2 Ceramic Substrate Centering Unit User Manual SIPLACE HS-50
2.3 Mechanical Ceramic Substrate Centering Software Version SR.502.xx 01/01 Issue
42
Key:
1. Stop unit Kit 1, fixed stop
2. Stop unit Kit 2, fixed stop
3. Stop unit Kit 2, fixed stop
4. Stop rail 1, 2 and 3, assembly (see marks
and
), movable stop
5. Parallel pin to limit the lift:
MUST be on stop rail 1.
NOTE:
Install the stop unit kit 1 (fixed stop) and stop rail "", assembly (= movable stop) for substrates
50mm to 62mm wide that are MORE than 50mm long (e. g., twice as long): See table,
Fig. 2.3 - 4, above and Fig. 2.3 - 5).

User Manual 2 Ceramic Substrate Centering Unit
Software Version SR.502.xx 01/01 Issue 2.3 Mechanical Ceramic Substrate Centering
43
DANGER
Only the line engineer is permitted to perform the following work.
The safety instructions in the chapter "Operational Safety" in the User Manual HS-50 take prece-
dence.
BEFORE any work, the machine must be switched OFF and isolated from the mains.
In addition, the compressed air feed must be switched OFF at the main valve of the compressed
air unit in the machine frame.
While working, secure the machine conscientiously against other persons and against being re-
started without authority. Proceed as described in the chapter "Locking of the Machine".
Å The movable component changeover table remains moved into place and connected.
Å Turn the machine OFF as described in the above DANGER text.
Å The mechanical ceramic substrate centering unit is left installed during the adapting to the sub-
strate size.
Å Move the Y-gantry in such a manner that the ceramic substrate centering unit is readily acces-
sible.
Å Loosen the screws fastening the stop rail to the X-slide unit (2 socket head hex cap screws M3:
see Fig. 2.3 - 6).
Å Install the stop rail required based on the substrate size (see table above).

2 Ceramic Substrate Centering Unit User Manual SIPLACE HS-50
2.3 Mechanical Ceramic Substrate Centering Software Version SR.502.xx 01/01 Issue
44
Å Back out the screws fastening the stop unit to the X-slide unit (2 socket hex had cap screws
M3).
Å Install the stop unit required for the particular substrate size (kit 1, 2 or 3, see table,
Fig. 2.3 - 4, above).
Å Turn ON the machine and the compressed air.
Å If necessary, conduct a test run with substrate (see Section 2.7).
NOTE:
If the substrate is lifted when the open centering unit moves upward, the LINE ENGINEER must
adjust the stopper position, as described in Section 2.3.7.
1RWHVRQ2SHUDWLRQ
The type of illumination of the position recognition (see Section 2.2) must correspond to the fidu-
cials on the substrate.This does not apply if a PCB camera multicolor is being used.
The operation during the placement run corresponds to the steps during PCB placement.
Roller
2 socket hex
head screws
Stop unit
with roller
Stop rail with
ball bearings
X-slide unit
(3 versions)
(3 versions)
M3 x 8
Connection
rail must be
removed!
Distance bolt
AND
distance bolt
7UDQVSRUWGLUHFWLRQ
2 socket hex
head screws
M3 x 8