00192791-02 - 第45页

User Manual 2 Ceramic Substrate Centering Unit Software Version S R.502.xx 01/01 Issue 2.3 Mechanical Ceramic Substrate Centering 45 Using th e singl e functio n "Ceram ic sub strate cen tering" in the conveyor…

100%1 / 66
2 Ceramic Substrate Centering Unit User Manual SIPLACE HS-50
2.3 Mechanical Ceramic Substrate Centering Software Version SR.502.xx 01/01 Issue
44
Å Back out the screws fastening the stop unit to the X-slide unit (2 socket hex had cap screws
M3).
Å Install the stop unit required for the particular substrate size (kit 1, 2 or 3, see table,
Fig. 2.3 - 4, above).
Å Turn ON the machine and the compressed air.
Å If necessary, conduct a test run with substrate (see Section 2.7).
NOTE:
If the substrate is lifted when the open centering unit moves upward, the LINE ENGINEER must
adjust the stopper position, as described in Section 2.3.7.
 1RWHVRQ2SHUDWLRQ
The type of illumination of the position recognition (see Section 2.2) must correspond to the fidu-
cials on the substrate.This does not apply if a PCB camera multicolor is being used.
The operation during the placement run corresponds to the steps during PCB placement.
Roller
2 socket hex
head screws
Stop unit
with roller
Stop rail with
ball bearings
X-slide unit
(3 versions)
(3 versions)
M3 x 8
Connection
rail must be
removed!
Distance bolt
AND
distance bolt
7UDQVSRUWGLUHFWLRQ
2 socket hex
head screws
M3 x 8
User Manual 2 Ceramic Substrate Centering Unit
Software Version SR.502.xx 01/01 Issue 2.3 Mechanical Ceramic Substrate Centering
45
Using the single function "Ceramic substrate centering" in the conveyor menu it is possible to open
and close the mechanical substrate centering unit for test purposes (see Section 2.7.1).
After placing a substrate in the input conveyor, it is possible to conduct a substrate trial run as de-
scribed in Section 2.7.1 using the "Single functions" of the processing conveyor.
 (UURU0HVVDJHV3RVVLEOH&DXVHVDQG5HPHG\
In case of raising the substrate during the centering process -> see Section 2.3.7.
In the event of an error, one of the following error messages is output at the station’s operator in-
terface:
"Error, ceramic substrate centering 1" or
"Error, ceramic substrate centering 2"
This stops the placement process.
The messages mean that the required condition of the mechanical substrate centering unit "open"
/ "closed"), which is interrogated by the proximity switch of the substrate centering unit, is absent.
Addition

means: The error is in processing area 1 or 4 (see Fig. 2.3 - 1).
Addition
means: The error is in processing area 2 or 3 (see Fig. 2.3 - 1).
Possible causes:
There is a mechanical obstruction,
e.g., due to a component that is wedged in place and is preventing the X-slide from moving:
Å Remove the wedged component with a vacuum cleaner or, if necessary, with tweezers as
described under "Weekly Maintenance" in the Section 2.4.
Ther is a malfunction at the tension spring on the flat cylinder:
Å Remedy the malfunction as described under "Monthly Maintenance" in Section 2.5.
There is another malfunction:
Defect of the proximity switch / solenoid valve / leaky pneumatic connection, not plugged in
properly, cable conductors broken.
Å Notify the line engineer / service technician.
2 Ceramic Substrate Centering Unit User Manual SIPLACE HS-50
2.3 Mechanical Ceramic Substrate Centering Software Version SR.502.xx 01/01 Issue
46
 3UREOHP5HVROXWLRQ6XEVWUDWHLVUDLV HG
 &KHFNLQJWKH6WRSSHU3RVLWLRQ
While the substrat is beeing raised during the centering process os the substrate centering unit
conduct the following test run with substrate to check the psoitin of the stopper.
NOTICE
These jobs must be carried out for each ceramic substrate centering unit, i.e., for each processing
area.
When the centering unit is open, the substrate edge pointing in the direction of the unloader must
still be 0.5 mm IN FRONT OF that of the unmovable roller of the fixed stop (see Fig. 2.3 - 8).
When the substrate is raised while the centering unit is moving upward, the stopper position must
be adjusted - in the direction of the X-centering station -> Only by LINE ENGINEER.
Å Select the menu "Transport functions".
Å Place the substrate on the input belt
Å During the following step, keep an eye on the substrate and the closing movement of the X-
centering unit
± 7KHVXEVWUDWHLVQRWWRUDLVH
Å For the corresponding conveyor (processing area), select: PCB onto processing belt 1.
Å Select:PCB onto intermediate belt.
Å Carry out the above-described check on the function and the substrate/stopper position for pro-
cessing belt 2.
Select: PCB onto processing belt 2.
Å Select: PCB onto output belt.
Å If the stopper is in the right position, conduct a trial placement with substrate and check
whether the fiducials of the substrate can be reliably recognized. If necessary, select a different
type of illumination (see User Manual).
Å If the substrate is lifted when the open centering unit moves upward, the LINE ENGINEER
must adjust the stopper position (see Section 2.3.7.2).