OM-1058-002 - 第23页

Tg0409-PM-SO 0410-002 22 2.3 Component Pick-up Position Alignment Press Feed Lever • For tape feeders of 12 mm or wider , push the feed lever of the feeder set jig and align the component center with the component center…

100%1 / 105
Tg0409-PM-SO
Fig. 33
Press
Feed Lever
Component
0410-002 21
2.3 Component Pick-up Position Alignment
2.3 Component Pick-up Position Alignment
To pick up a component correctly, the component center is aligned with the
pick-up position.
If the component center is not aligned with the pick-up position,
then the pick-up cannot proceed correctly.
Notice
For 8 mm width tape feeder, press the
feed lever to feed the tape as if there is a
component on the pick-up position.
Tg0409-PM-SO0410-002 22
2.3 Component Pick-up Position Alignment
Press
Feed Lever
For tape feeders of 12 mm or wider, push
the feed lever of the feeder set jig and align
the component center with the component
center set position.
The component center set position is marked on
the suppressor and the body section.
Marking
Marking
Fig. 34
Fig. 35 Marking (Suppressor)
Fig. 36 Marking (Body Section)
The Component Center Positions and
Component Center Set Positions for TF-
1210, TF-1211, TF-1212, TF-1610, TF-
2410, TF-3210 and TF-4410 (The figure
shows TF-2410).
The set position is the same as the pick-up
position.
The Component Center and Component
Center Set Position for TF-2411 and TF-
3211(The figure shows TF-2411).
The component center is set at a position
different from that of the pick-up because
the feeder is for two or more feedings.
Forward Direction
Component Center Set
Position (Pick-up Position)
24
Forward Direction
Component Center Set Position
for the Feeders with Two or More
Feeding Operations
On tape feeders with two or
more feedings, the feed pitch
amount is marked.
Fig. 37
Fig. 38
Note
Note
Tg0409-PM-SO0410-002 23
2.3 Component Pick-up Position Alignment
Component Center and Component Center
Set Position for TF-4411 (In the case of tape
feeds of 24 mm pitch)
The set position varies with the pitch.
Two or more tape feedings are required, so
set the component center position slightly
away from the pick-up position.
Component Center and Component Center
Set Position for TF-4411 (In the case of tape
feeds of 32 mm pitch)
Notice
:
:

:
Forward Direction
Component Center Set Position for Tape
Feeds of 24 mm pitch
4/3
3
3
2
3
4
4
4X
2
2
44X24
/
3
2
Forward Direction
Component Center Set Position for Tape
Feeds of 32 mm pitch
Fig. 39
Fig. 40
Note