1. Select “OUTPUT 1” and “Dark ON”. (Switch OUTPUT)
1) Press the [Mode] key.
If you hold down the [MODE] key for one (1) second, the output mode is switched between
“OUTPUT 1“ and “OUTPUT 2”.
2) Press the [L/D] key.
Through-beam type: Set to “Dark ON” so that the OUTPUT is turned ON with a work piece in
the detection range.
The “D” light of [L/D Indicator] turns ON.
Figure 17
2. Select “Detailed Setting”. (Switch Function)
Hold down the [MODE] key for three (3) seconds or more to switch the OUTPUT mode between
RUNand SET”.
Select the detailed setting (“FUnCoPt”) by pressing the [UP/DOWN] key, and then press the
[MODE] key.
Figure 18
3. Set the “Detection function” to “SHS” mode.
Select “SHS” mode by pressing the [UP/DOWN] key and then press the [MODE] key.
Figure 19
4. Set the “DPC” function to “ON”.
In order to stabilize the detection performance regardless of the amount of the incident light, set
the “DPC” to ON”.
Select “DPC ON” by pressing the [UP/DOWN] key and then press the [MODE] key.
As the setting for “Timer” function is not required, press the [MODE] key and skip it.
Figure 20
OUT indicator (OUTPUT 1)
Hold down the [MODE]
key for 1 second.
Hold down the [MODE] key for
3 seconds or more.
Basic setting
Detailed setting
HS: High-Speed mode
GIGA: Giga mode
STND: Standard mode
SHS: Super High-Speed mode
HS: High-Speed mode
STND: Standard mode
Service Engineer
Service Information
SI1407002E-000=YSM40_How to change the board flow direction (Tentative measure)
16/24
5. Set the Power tuning level to “2000”.
Set the target incident light level (Power tuning level) to “2000”.
You can set the power tuning level by pressing the [UP/DOWN] key. (Default: 9999. It is possible
to set from 1 through 9999.)
There are other items such as “BANK switching” and “Power Tuning ON/OFF Setting”. As the
settings for these items are not required, press the [MODE] key and skip it.
Figure 21
6. Set the Percentage Tuning to “ON” and the Tuning level to “-50%”.
Perform the setting to detect transparent objects and microscopic objects.
You can set the Percentage Tuning level by pressing the [UP/DOWN] key. (Default: -6%. It is
possible to set from -99% through 99%.)
Figure 22
7. Set the “External Input” to LoFF”.
Change the type of the external light.
Select “LoFF” by pressing the [UP/DOWN] key and then press the [MODE] key to set.
Figure 23
8. Set “Inverted Display” toON”.
The digital display may be inverted depending on the mounting position of the amplifier. In this
case, set the “Inverted Display” to ON.
Figure 24
9. Switch the mode from “SETto RUN”.
After completing the procedures from step 3 through step 8, hold down the [MODE] key for three
(3) seconds or more to change the mode from “SETto RUN.
10. Perform the Percentage Tuning.
Make sure that there is no board to be detected by the target sensor, and hold down the [S.TUNE]
key for one (1) second or more.
Figure 25
Tuning OFF
Tuning ON
Tuning OFF
Tuning ON
Hold down the [S.TUNE] key for 1 second or more. Make sure that the
incident light level is “2000” and the Threshold level is “1000”.
(The values may slightly vary depending on the adjustment state.)
Service Engineer
Service Information
SI1407002E-000=YSM40_How to change the board flow direction (Tentative measure)
17/24
3. Things to do after changing the board flow direction
3.1 Change the machine setting
Change the setting of the board flow direction.
Click the [Machine] button and select “Setting” “Machine Information” “Installation Setting
from the tree view on the left side of the VmSpec window and change the setting of “Conveyor
Direction”.
No password is required for changing the setting.
Caution:
Make sure to restart the machine after changing the setting of the board flow direction for the changes
to take effect.
The setting cannot be changed by just reading the board data, as the parameter is related to the drive
section.
Figure 26
3.2 Adjustments to be performed by the CalibSm
After changing the board flow direction and adjust the positions of the sensors, the following
adjustments need to be performed by the CalibSm.
[112 Check Conveyor]
[113 Transfer Distance]
[024 ANC Auto]