Installation Final Work Interior Lighting Innenraumbeleuchtung 45 3.3 3 . 3 F in a l W o r k Final Work ► Close all covers. ► Switch on the machine ► Move the component trolley into the mach ine. ► Close the cover. The s…

100%1 / 48
Installation
Installing the Interior Lighting
44 Interior Lighting Innenraumbeleuchtung
Cable routing
During installation, the cable must be routed to the distrib-
utor in section 2.
Route the cable to the side and fix it with an adhesive
mounting base (1).
Secure the connectors on the extension cable at the
machine frame.
Route the extension cable between the machine
frame and the ceiling of the machine interior (2) and
(3).
Cable routing
Route the extension cable along the ceiling of the ma-
chine interior towards location 1, sector 2.
Fix the cable with an adhesive mounting base (1) and
to the provided bolt using a cable clamp (2).
Use an M4 self-securing screw nut.
Route the cable down the machine base towards the
distributor (3).
Secure the cable using a cable tie.
Additionally, fix the cable to the provided bolt on the
fan using a cable clamp.
Installation
Final Work
Interior Lighting Innenraumbeleuchtung 45
3.3
3.3 Final Work
Final Work
Close all covers.
Switch on the machine
Move the component trolley into the machine.
Close the cover.
The station software automatically detects that the interior lighting is installed and controls its function
accordingly:
The interior lighting is switched on if the safety circuit is opened, for example if the cover is opened.
The interior lighting is switched off if the machine is in production mode.
Connecting the extension cable to the distributor
Open the distributor door in sector 2 of location 1.
Find the connector X18qa.
Connect the extension cable to connector X18qa (1).
Close the distributor door.
NOTICE
Function test
For testing the function, you can switch on the interior lighting via the I/O functions. Make
sure to switch it of before starting a production as the placement accuracy may be ham-
pered by external light.