3-2-16
PCB warpage detection
error 1
Describes how to handle the PCB warpage detection error.
1
There are five types for error;
A:PCB warpage range over, B:PCB warpage possible range error, C:PCB warpage result grade error, D:PCB
warpage measurement error, E:PCB warpage correction disabled
If PCB warpage detection error occurs, the following four types of handling methods are available.
(1)Re-measuring the PCB warpage shape
Return to the main menu and start the production again
(2)Removing the error PCB
Perform the following flow
+
2
2
(Return to the Home screen)
1
Handling method Error type
(1) Re-measuring the PCB warpage shape A, B, C
(2) Removing the error PCB A, B, C
(3) Changing the PCB warpage grade
tolerance
C