N7201A616E00_0317 - 第267页
NPM-W 2 EJM7DE-MB-03O-0 0 3-3-4 -2 Production

NPM-W2 EJM7DE-MB-03O-00
Defective components supplied from a tray feeder are ejected to an ejection pallet.
If the ejection pallet is full and the nozzle picks up ejected components during production, this message
appears.
Compo-
nent
supply
Ejection pallet
Operating procedure
3-3-4
■If ‘Use tray supply side” is “ON” (If the ‘Set’ item below is ‘ON’)
1
1
Confirm the message, and
perform any of the followings
A
A
A
A
Use tray supply side
(→ P.7-1-1 ‘Option setting’)
■[Machine] - [Setting] - [Tray] - [Option] screen
■If ‘Use tray supply side” is “OFF” (If the ‘Set’ item below is ‘OFF’)
If the ejection pallet is full, it moves to the refill section: therefore you replace the
tray.(→P.3-3-3 ‘Tray replacement (tray feeder)’)
the ejection pallet is full, the machine stops in error; therefore you replace the
magazine.
(→P.2-4-2-5 ‘Removing the magazine from the tray feeder’)
3-3-4-1

NPM-W2 EJM7DE-MB-03O-00
3-3-4-2
Production

NPM-W2 EJM7DE-MB-03O-00
OFF
SERVO
3-4-1
Setting production
materials 1 (dispensing head)
It explains in the case that the dispensing head is attached to the rear side and operation is performed
from the front side.
Operating procedure
3-4
1
ENABLING
2 3
Move the head to
the replace
position
6
Detach a syringe
Pull the syringe straight up.
Syringe
1
2
1
2
Θ-axis
●Be careful not to apply force to the protection cover
for the X-axis linear scale during syringe replacement.
There is possibility for interference with the linear
scale reading head due to cover deformation.
SC-axis
Lock plate
●Be careful not to turn the gear of SC-axis in a
clockwise direction during syringe replacement,
otherwise, adhesive may leak.
Linear scale
protection cover
Turn the lock plate clockwise to
release the syringe lock.