NPM-W 2 EJM7DE-MB-05O-0 0 Wr ong judgment input scr een 2 Operating procedure 5-4-4 A E B Comment C Pattern No G Return to the previous screen. MeasV al Displays the measurement value per defect item. Fill rate NG: Area …

100%1 / 714
NPM-W2 EJM7DE-MB-05O-00
H
The displayed inspection point is set as
misjudgment (conforming).
I
The displayed inspection point is set as
nonconforming but placement to the
position is carried out.
J
The displayed inspection point is set as
nonconforming.
K
Displays the screen for NG detail
information.
L
All the undefined inspection-NG points
are collectively set as nonconforming.
The batch setting button cannot be
used unless all inspections are
complete.
5-4-4-2
Solder
inspection
NPM-W2 EJM7DE-MB-05O-00
Wrong judgment input
screen 2
Operating procedure
5-4-4
A
E
B
Comment
C
Pattern No
G
Return to the previous screen.
MeasVal
Displays the measurement value per defect
item.
Fill rate NG: Area rate [%]
Pervasion rate NG: Area rate [%]
Bridge NG: Bridge width [mm]
Misalignment X NG: Misalignment X [mm]
Misalignment amount Y NG: Misalignment
Y [mm]
Shape error NG: Abnormal shape rate [%]
GD
A
D
Bad item
Displays the defect item name regarding
solder displayed on the screen.
B C
E F
Comp info
Name of a placement component (part
name).
F
Threshold
Display the threshold per defect item
Fill rate NG:
Lower limit threshold of area rate NG [%]
Pervasion rate NG:
Upper limit threshold of area rate NG [%]
Bridge NG:
Upper limit threshold of bridge width
NG [mm]
Misalignment amount X NG:
Upper limit threshold of misalignment X
NG [mm] (±)
Misalignment amount Y NG:
Upper limit threshold of misalignment Y
NG [mm] (±)
Shape error NG:
Upper limit threshold of abnormal shape
rate NG [%]
Produc-
tion
5-4-4-3
1
Over judge input
(Displays detailed NG information)
NPM-W2 EJM7DE-MB-05O-00
1
5-4-4-4
1
When setting the undefined on a per-solder basis
For over judge (OK judge)
(Over judge is set, and a component is
placed)
In the presence of other defective
solders, the next one is displayed.
For NG solder judge
(NG is set, and components are not
placed)
In the presence of other defective
solders, the next one will be displayed.
For NG placement
(NG is set, and a component is not
placed)
In the presence of other defective
solders, the next one will be displayed.
Solder
inspection