N7201A616E00_0317 - 第348页
NPM-W 2 EJM7DE-MB-05O-0 0 Wr ong judgment input scr een 2 Operating procedure 5-4-4 A E B Comment C Pattern No G Return to the previous screen. MeasV al Displays the measurement value per defect item. Fill rate NG: Area …

NPM-W2 EJM7DE-MB-05O-00
H
The displayed inspection point is set as
misjudgment (conforming).
I
The displayed inspection point is set as
nonconforming but placement to the
position is carried out.
J
The displayed inspection point is set as
nonconforming.
K
Displays the screen for NG detail
information.
L
All the undefined inspection-NG points
are collectively set as nonconforming.
●The batch setting button cannot be
used unless all inspections are
complete.
5-4-4-2
Solder
inspection

NPM-W2 EJM7DE-MB-05O-00
Wrong judgment input
screen 2
Operating procedure
5-4-4
A
E
B
Comment
C
Pattern No
G
Return to the previous screen.
MeasVal
Displays the measurement value per defect
item.
Fill rate NG: Area rate [%]
Pervasion rate NG: Area rate [%]
Bridge NG: Bridge width [mm]
Misalignment X NG: Misalignment X [mm]
Misalignment amount Y NG: Misalignment
Y [mm]
Shape error NG: Abnormal shape rate [%]
GD
A
D
Bad item
Displays the defect item name regarding
solder displayed on the screen.
B C
E F
Comp info
Name of a placement component (part
name).
F
Threshold
Display the threshold per defect item
Fill rate NG:
Lower limit threshold of area rate NG [%]
Pervasion rate NG:
Upper limit threshold of area rate NG [%]
Bridge NG:
Upper limit threshold of bridge width
NG [mm]
Misalignment amount X NG:
Upper limit threshold of misalignment X
NG [mm] (±)
Misalignment amount Y NG:
Upper limit threshold of misalignment Y
NG [mm] (±)
Shape error NG:
Upper limit threshold of abnormal shape
rate NG [%]
Produc-
tion
5-4-4-3
1
Over judge input
(Displays detailed NG information)

NPM-W2 EJM7DE-MB-05O-00
1
5-4-4-4
1
When setting the undefined on a per-solder basis
■For over judge (OK judge)
(Over judge is set, and a component is
placed)
●In the presence of other defective
solders, the next one is displayed.
■For NG solder judge
(NG is set, and components are not
placed)
●In the presence of other defective
solders, the next one will be displayed.
■For NG placement
(NG is set, and a component is not
placed)
●In the presence of other defective
solders, the next one will be displayed.
Solder
inspection