N7201A616E00_0317 - 第406页

NPM-W 2 EJM7DE-MB-06O-0 0 Setting the dispensing timing condition From [Dispensing condition] screen ( → P.6-1-15- 1 ) Only when the dispensing ti ming control is set to[ON] A B C E D A Dispenser height (mm) The distance…

100%1 / 714
NPM-W2 EJM7DE-MB-06O-00
6-1-15-2
I
J
K
L
M
G
H
100%
80%
60%
40%
20%
Dispenser Rise Speed
Dispenser Descend Speed
Dispensing time (s)
Head rise pos (mm)
Dispenser time ctrl
Whether the dispending timing is
controlled or not is displayed,
Head Stop Position (mm)
Dispenser type
The dispensing type is displayed.
The data cannot be modified on the
machine.
Choose the ascent velocity of a syringe.
Choose the decent velocity of a syringe.
The order for choosing the velocity is as
same as ‘Dispenser Rise Speed.’
The distance between PCB upper
surface and the nozzle lower end.
Set value: 0.001 mm to 30.0 mm
Setting
change
NPM-W2 EJM7DE-MB-06O-00
Setting the dispensing timing condition
From [Dispensing condition] screen ( P.6-1-15-1)
Only when the dispensing timing control is set to[ON]
A B C
E D
A
Dispenser height (mm)
The distance from the nozzle tip to the
upper surface of the PCB where
dispensing is started is displayed.
B
Dispenser Rise Speed2
The dispensing rising speed (second
step) is displayed.
C
Dispenser Descend Speed2
The dispensing lowering speed (second
step) is displayed
D
Wait time1 (s)
The waiting time at the bottom dead
point in dispensing is displayed.
E
Wait time2 (s)
The waiting time after rising in
dispensing is displayed.
Z
Dispenser
height
Dispensing
lowering speed
1st step
Dispensing
start
Waiting time at the
bottom dead point in
dispensing
Dispensing
rising speed
2nd step b
Waiting time
after rising
During dispending
Dispensing
rising speed
1st step
Time
PCB top
surface
a
d
e
Dispensing
lowering speed
2nd step
c
Data
editing
Dispensing condition
data edit 2 (dispensing head)
Operating procedure
6-1-15
6-1-15-3
NPM-W2 EJM7DE-MB-06O-00
Setting the multipoint coordinates
From [Dispensing condition] screen ( P.6-1-15-1)
Only when the multipoint dispensing data exists
A
B
A
Pos Cnt
The number of points of multipoint
dummy dispensing for the applicable
component list is displayed.
B
No
The number in sequence is displayed.
C
X[mm]
X dispensing coordinate is displayed.
D
Y[mm]
Y dispensing coordinate is displayed.
E
A[°]
θ dispensing coordinate is displayed.
C D E
6-1-15-4
Setting
change