N7201A616E00_0317 - 第408页

NPM-W 2 EJM7DE-MB-06O-0 0 Setting the drawing condition From [Dispensing condition] screen ( → P.6-1-15- 1 ) Only when the draw ing data exists A C D E A Draw Movement Speed (mm/s) B ‘Draw Movement W ait Time (s) Set the…

100%1 / 714
NPM-W2 EJM7DE-MB-06O-00
Setting the multipoint coordinates
From [Dispensing condition] screen ( P.6-1-15-1)
Only when the multipoint dispensing data exists
A
B
A
Pos Cnt
The number of points of multipoint
dummy dispensing for the applicable
component list is displayed.
B
No
The number in sequence is displayed.
C
X[mm]
X dispensing coordinate is displayed.
D
Y[mm]
Y dispensing coordinate is displayed.
E
A[°]
θ dispensing coordinate is displayed.
C D E
6-1-15-4
Setting
change
NPM-W2 EJM7DE-MB-06O-00
Setting the drawing condition
From [Dispensing condition] screen ( P.6-1-15-1)
Only when the drawing data exists
A C D
E
A
Draw Movement Speed (mm/s)
B
‘Draw Movement Wait Time (s)
Set the wait time (the time from when the
nozzle starts descending after traveling on
the XY unit until when it travels the
descending XY distance).
( 0.00 s to 9.99 s)
Use this in such a case that the dispensing
shape of the starting point of drawing is
unstable.
C
Draw Movement Stop Time (s)
Set the draw movement stop time (the time
during which the dispenser movement stops
in order to change the draw direction).
( 0.00 s to 9.99 s)
Use this in such a case that the dispensing
becomes excessive in amount when the
draw direction is changed.
D
Sack Back Time (s)
Set the sack back time (the time to put
materials back in the nozzle by
reversing the nozzle at the end of draw
movement.
( 0.00 s to 9.99 s)
Use this in such a case that the draw
shape is unstable at the end of drawing.
E
‘Rise Wait Time (s)
Set the raise wait time (the time
between the end of drawing and the
nozzle raised).
( 0.00 s to9.99 s)
Use this in such a case that the draw
shape is unstable at the end of drawing.
(the time following the Sack Back Time.)
B
FGH
F
Rise Waiting Pos(mm)
Set the raise pos of waiting pos order
(the raised position of the nozzle before
making the next draw movement at the
completion of a draw movement).
( 2.500 mm to 25.000 mm)
You can set it below the setting value of
“Head raised position” in the Dispenser
Condition.
G
Wait Time After Rise (s)
Set the wait time after raise (the time
from when the nozzle rises after draw
movement until when the XY unit starts
to make the next draw movement).
( 0.00 s to 9.99 s)
H
Dummy dispensing existence
Whether dummy dispensing is
performed or not before drawing is
displayed.
Data
editing
Dispensing condition
data edit 3 (dispensing head)
Operating procedure
6-1-15
6-1-15-5
NPM-W2 EJM7DE-MB-06O-00
Setting the drawing coordinates
From [Dispensing condition] screen ( P.6-1-15-1)
Only when the drawing data exists
A
B
A
Pos Cnt
The point of draw coordinate in the
applicable list is displayed.
B
No
The number in sequence is displayed.
C
X[mm]
X dispensing coordinate is displayed.
D
Y[mm]
Y dispensing coordinate is displayed.
E
Pattern
Action pattern of the applicable
coordinate data is displayed.
For ‘Move’
XY unit only move without
dispensing or drawing.
For ‘Straight’
Draw straight line from the previous
coordinate.
For ‘Dispense’:
Perform dot dispensing.
C D E
6-1-15-6
Setting
change