N7201A616E00_0317 - 第413页

NPM-W 2 EJM7DE-MB-06O-0 0 6-1-17 -2 A Dispense Coordinate The coordinat e of the dispense poin t for local height meas urement is disp layed. B CompName/PL,PN,BC,DC,Comnt The display of ‘Component name’ and ‘PL,PN,BC,DC,…

100%1 / 714
NPM-W2 EJM7DE-MB-06O-00
6-1-17-1
A
A
Dispensing data edit
(dispensing head)
DspPoints
You can check and modify the dispensing data.
C
The total number of dispensing points is
displayed.
B
SkipPoints
The total number of skipped points is
displayed.
C
SEQ.
The sequence number of the dispensing
point is displayed.
D
X[mm], Y[mm], A[°]
Dispensing-point coordinates are
displayed.
E
P
An order of priority of dispensing point is
displayed.
Blank when the PCB is placed after
dispensing.
When dispensing and placement are
performed alternatively, ‘L’ is displayed
for as a priority.
F
CompName/PL,PN,BC,DC,Com
nt
Switches the display between
‘CompName’ and ‘PL, PN, BC, DC,
Comnt’ (part list number of linked
components, pattern recognition number
of dispensing point data, dispensing
condition of dispensing point data,
numbers of multipoint/dispensing of
linked component data (0 for invalid
multipoint/dispensing),comment).
G
Shows the rest of the component name
by scrolling.
B
D E F G
L
I
H
K
J
H
Coordinate reference bitmap
display
The bitmap showing the coordinate
reference is displayed.
I
Sets/Clears the skip settings.
J
Searches SEQ, coordinates, and
comments.
K
Scrolls up and down the list.
L
The local height measurement data is
displayed.
The transit is possible only if the local
height measurement data is set.
Data
editing
Operating procedure
6-1-17
NPM-W2 EJM7DE-MB-06O-00
6-1-17-2
A
Dispense Coordinate
The coordinate of the dispense point for
local height measurement is displayed.
B
CompName/PL,PN,BC,DC,Comnt
The display of ‘Component name’ and
‘PL,PN,BC,DC, Comment’ (the parts list
number to be linked, the pattern
identification number of the dispense
point data, the dispense condition of the
dispense point data, multiple points of
the parts data to be linked and drawing
points (multiple points and drawing is
invalid = 0) and comment) are switched.
C
D
Warp Correct Mode
The height correction mode is displayed.
Average:
Average of the measurement result
shall be the offset value.
Max.:
Maximum value of the measurement
result shall be the offset value.
Auto:
Average and maximum value are
automatically selected and these data
shall be the offset value.
Local height measurement data
The data of the local height measurement for dispense coordinate is entered and modified
1
1
A
D
B C
E F G
Shows the rest of the component name
by scrolling.
E
X[mm]
X coordinate of local height
measurement point is displayed.
F
Y[mm]
Y coordinate of local height
measurement point is displayed.
G
The skip is set or reset.
Setting
change
NPM-W2 EJM7DE-MB-06O-00
EC D
6-1-18-1
F
A
You can set various data for dummy dispensing operations.
The dummy data of an applicable
nozzle position is displayed.
B
The basic condition setting items are
displayed.
C
The operation condition setting items
are displayed
D
The dispensing timing condition setting
items are displayed. This is active only
when the dispensing timing control is
set “ON.”
E
The condition setting items used in
dummy dispensing on a PCB are
displayed. This is active only when the
dummy dispensing pattern shows
“PCB.”
A
1
GB
Basic setting
1
F
Nozzle No
G
Nozzle Name
Dummy dispensing
data edit 1 (dispensing head)
Data
editing
Operating procedure
6-1-18