NPM-W 2 EJM7DE-MB-06O-0 0 E C D 6-1-18 -1 F A You can set various data for dummy dispensing ope rations. The dummy data of an applicable nozzle position is displayed. B The basic condition setting items are displayed. C …

100%1 / 714
NPM-W2 EJM7DE-MB-06O-00
6-1-17-2
A
Dispense Coordinate
The coordinate of the dispense point for
local height measurement is displayed.
B
CompName/PL,PN,BC,DC,Comnt
The display of ‘Component name’ and
‘PL,PN,BC,DC, Comment’ (the parts list
number to be linked, the pattern
identification number of the dispense
point data, the dispense condition of the
dispense point data, multiple points of
the parts data to be linked and drawing
points (multiple points and drawing is
invalid = 0) and comment) are switched.
C
D
Warp Correct Mode
The height correction mode is displayed.
Average:
Average of the measurement result
shall be the offset value.
Max.:
Maximum value of the measurement
result shall be the offset value.
Auto:
Average and maximum value are
automatically selected and these data
shall be the offset value.
Local height measurement data
The data of the local height measurement for dispense coordinate is entered and modified
1
1
A
D
B C
E F G
Shows the rest of the component name
by scrolling.
E
X[mm]
X coordinate of local height
measurement point is displayed.
F
Y[mm]
Y coordinate of local height
measurement point is displayed.
G
The skip is set or reset.
Setting
change
NPM-W2 EJM7DE-MB-06O-00
EC D
6-1-18-1
F
A
You can set various data for dummy dispensing operations.
The dummy data of an applicable
nozzle position is displayed.
B
The basic condition setting items are
displayed.
C
The operation condition setting items
are displayed
D
The dispensing timing condition setting
items are displayed. This is active only
when the dispensing timing control is
set “ON.”
E
The condition setting items used in
dummy dispensing on a PCB are
displayed. This is active only when the
dummy dispensing pattern shows
“PCB.”
A
1
GB
Basic setting
1
F
Nozzle No
G
Nozzle Name
Dummy dispensing
data edit 1 (dispensing head)
Data
editing
Operating procedure
6-1-18
NPM-W2 EJM7DE-MB-06O-00
6-1-18-2
Dispenser Rise Speed
Scrolls up and down the list.
L
HIJK
M N O Q
Dispenser time ctr
This shows whether the dispensing
timing control function is enabled or
disabled.
Dispenser Descend Speed
Dispenser time (s)
Head rise pos (mm)
Dummy dispensing pattern
Dispenser count
RecogExist
Recognition retry count
H
I
100%
80%
60%
40%
20%
K
L
J
K
M
N
O
P
Choose the ascent velocity of a syringe.
Choose the decent velocity of a syringe.
The order for choosing the velocity is as
same as ‘Dispenser Rise Speed.’
Choose the location for dummy dispensing.
Setting
change