N7201A616E00_0317 - 第418页

NPM-W 2 EJM7DE-MB-06O-0 0 6-1-18 -5 Setting PCB dummy dispensing Only when the dummy dispensing pattern is [PCB]) A A Start coord X (mm) The start X coordinate of dummy dispensing is displa yed. 1 1 B C D E B Start coord…

100%1 / 714
NPM-W2 EJM7DE-MB-06O-00
6-1-18-4
Setting the dispensing timing
Only when the dispensing timing control is set to [ON]
A
A
Dispenser height (mm)
The distance from the nozzle tip to the
upper surface of the PCB where dispensing
is started is displayed.
1
1
B C D E
B
Dispenser Rise Speed2
The dispensing rising speed 2 is
displayed.
C
Dispenser Descend Speed2
The dispensing lowering speed 2 is
Displayed.
D
Wait time1 (s)
The waiting time at the bottom dead
point in dummy dispensing is displayed.
E
Wait time2 (s)
The waiting time after rising in dummy
dispensing is displayed.
Z
Dispenser
height
Dispensing
lowering speed
1st step
Dispensing
start
Waiting time at the
bottom dead point in
dispensing
Dispensing rising
speed 2nd step b
Waiting time
after rising
during dispensing
Dispensing
rising speed
1st step
Time
Upper surface of
the dummy
dispensing unit
a
d
e
Dispensing
lowering speed
2nd step
c
Setting
change
NPM-W2 EJM7DE-MB-06O-00
6-1-18-5
Setting PCB dummy dispensing
Only when the dummy dispensing pattern is [PCB])
A
A
Start coord X (mm)
The start X coordinate of dummy
dispensing is displayed.
1
1
B C D E
B
Start coord Y (mm)
The start Y coordinate of dummy
dispensing is displayed.
C
Dispenser dire
The direction of dummy dispensing on a
PCB is displayed
D
Dispenser angle
E
Dispenser pitch (mm)
Data
editing
Operating procedure
6-1-18
Dummy dispensing
data edit 3 (dispensing head)
0°
90°
180°
270°
Choose the angle of a dispensing head
as the stopper does not contact to the
electrode.
You are allowed to enter the value
when [PCB] is selected on [Dummy
dispensing pattern].
NPM-W2 EJM7DE-MB-06O-00
6-1-18-6
Setting
change