N7201A616E00_0317 - 第424页

NPM-W 2 EJM7DE-MB-06O-0 0 Data editing Libr ar y c hec k 1 Describes how to check available nozzle s or feeder information. ● Edit on NPM-DGS if necessary. Nozzle library (placement head) 6-1-21 -1 Operating procedure 6-…

100%1 / 714
NPM-W2 EJM7DE-MB-06O-00
6-1-20-2
Setting
change
6-1-20-2
Setting
change
Item Description
Safe mode action
(For 3-nozzle head)
Perform the following when [ON] is set.
Do not allow superposition of X-axis, Y-axis and Y-axis during
pickup or placement
Do not allow preliminary lowing during pickup or placement.
Pickup check is performed by the vacuum sensor before X-axis or
Y-axis are moved during pickup or placement, and if pickup error is
detected, the action stops regardless of pickup error count.
High production
mode(F)
Perform the following when [ON] is set.
Production is performed in high-production mode on the machine
front side
*1) *2) *3)
High production
mode(R)
Perform the following when [ON] is set.
Production is performed in high-production mode on the machine
rear side.
*1) *2) *3)
*1)
It is enabled when the light weight 16-/12-nozzle head is installed.
*2)
When OFF is set, production is performed in “High-accuracy mode”.
*3)
About “High-production mode” and “High-accuracy mode”. (P.9-1-1 ‘Basic performance’)
NPM-W2 EJM7DE-MB-06O-00
Data
editing
Library check 1
Describes how to check available nozzles or feeder information.
Edit on NPM-DGS if necessary.
Nozzle library (placement head)
6-1-21-1
Operating procedure
6-1-21
A
B
H
Max Height
F
G
Pickup height
Size X/Size Y
C
E
Nozzle information
(P.6-1-21-1, -2)
NozzleName
Nozzle total height.
Unit: mm.
The height from the nozzle top to the
pickup surface.
Unit: mm.
The dimension in the X-/Y-direction as
seen from the top of the nozzle.
Unit: mm.
C A
B
Shows the previous or next table.
(Scrolls the table to the right.)
D
NzlNo.
I
Recog Mode
Nozzle recognition method.
Recognition
mode
Nozzle recognition
method
Reflect Reflection recognition
Transparency Transparency recognition
Both
Available for both
reflection and
transparency recognition
NPM-W2 EJM7DE-MB-06O-00
6-1-21-2
L
Pickup keep
The time to lower the transfer head
while a component is picked up.
Unit: ms.
Whether a pickup learning
function is enabled or not.
Pickup Learn
O
Mount Check
P
Nozzle Check
Q
Whether a placement check by a flow
sensor is enabled or not.
Nozzle existence.
J
K
L
M
N
O
P
J
Vacuum Break
The time interval from when the nozzle
has reached the placement bottom
dead point after switching the vacuum
break blow, while a component is
placed.
Unit: ms.
Vacuum Stand
The time interval from when the nozzle
has reached the pickup bottom dead
point after switching the vacuum valve,
while a component is picked up.
Unit: ms.
The table of nozzle information
C
Fixed column
Horizontal scrolling with or
A
Q
D F H
E G I
M
Mount Keep
The time to lower the transfer head
while a component is placed.
Unit: ms.
Studded Detect
N
Judgment value of nozzle clogging
detection.
K
Adhesion check
R
There is nozzle adhension check or not.
R
Setting