NPM-W 2 EJM7DE-MB-06O-0 0 ● After changing the disp ensing coordinates, press + , which allows you to perform the dispensing c oordinate pos ition teaching on the next coordinate s without any interruption. 6-2-13 -6 The…

100%1 / 714
NPM-W2 EJM7DE-MB-06O-00
6-2-13-5
When the position is misaligned
+
Adjust the lamp value
X/Y
Displays the inching amount of
positioning.
The view size of the recognition image is
switched.
The inching amount of positioning is
switched.
+
Creation procedure 2
Dispensing coordinates
teach 3
Produc-
tion data
teaching
Operating procedure
6-2-13
10
12
A
B
C
11
13
10
11
CB A
1312
NPM-W2 EJM7DE-MB-06O-00
After changing the dispensing
coordinates, press + ,
which allows you to perform the
dispensing coordinate position teaching
on the next coordinates without any
interruption.
6-2-13-6
The dispensing position teach
screen is exited, transitioning
to another screen
+
The camera moves to the next
measurement position. Go though the
step from to as well.
6
7
When the teaching of all the
measurement points is complete, the
center is calculated on the basis of the
taught coordinates, the data is saved,
and then the message indicating the
completion of measurement appears.
15
15
14
Setting
change
NPM-W2 EJM7DE-MB-06O-00
6-2-14-1
Dummy dispensing
teach 1 (dispensing head)
Produc-
tion data
teaching
Operating procedure
6-2-14
Inputting the dummy dispensing data
Inputting the dummy dispensing
recognition data
Starting the teaching
Setting the lamp values
Setting the area
Recognition
Saving data
Rechecking dummy dispensing
Unnecessary if the automatic
lamp setting is selected
Teaching is complete.
Checking dummy dispensing during production stop
Teaching Flow
Even while production is in progress after automatic operation starts, dummy dispensing
teaching is enabled only if the machine is at a standstill (single or immediate stop, cycle
stop, or single error stop).
Only when the dummy dispensing pattern is the unit, it can be performed in the same manner as in the
usual case.
If dummy dispensing is set to be performed on board, teaching is not available.
[Recog unit maintenance] operation cannot be performed on the priming shot confirm screen during
production stop.