Dummy dispensing
teach 1 (dispensing head)
Produc-
tion data
teaching
Operating procedure
6-2-14
Inputting the dummy dispensing data
Inputting the dummy dispensing
recognition data
Starting the teaching
Setting the lamp values
Setting the area
Recognition
Saving data
Rechecking dummy dispensing
Unnecessary if the automatic
lamp setting is selected
Teaching is complete.
Checking dummy dispensing during production stop
Teaching Flow
Even while production is in progress after automatic operation starts, dummy dispensing
teaching is enabled only if the machine is at a standstill (single or immediate stop, cycle
stop, or single error stop).
Only when the dummy dispensing pattern is the unit, it can be performed in the same manner as in the
usual case.
If dummy dispensing is set to be performed on board, teaching is not available.
[Recog unit maintenance] operation cannot be performed on the priming shot confirm screen during
production stop.
NPM-W2 EJM7DE-MB-06O-00
6-2-14-2
Setting
change
Adhesive dummy dispensing is checked for each head. When there are problems, you can change the set
values and recheck the operation.
A B C D E
F G H I
A
Nozzle No
B
Shot pos
The dummy dispensing position (PCB,
dummy dispensing unit).
C
RecogExist
Whether to perform recognition or not
during dummy dispensing.
D
Choose the head to check dummy
dispensing.
E
Choose whether or not to automatically
adjust the lamp value before dummy
dispensing recognition.
Yes:
Recognition is
carried out with the optimal lamp value
adjusted automatically.
No:
Recognition is carried out with the set lamp
value.
F
The recognition device maintenance
screen is displayed.
Press after displayed.
The screen cannot enter into other
screens.
G
The dummy dispensing data screen of
the target data (to modify) is displayed.
Press after displayed.
The screen cannot enter into other
screens.
H
The recognition unit maintenance screen is
displayed. When the screen is displayed,
press . The screen cannot enter into
other screens.
I
The reference area check screen is
displayed.
The total area value to be the reference
is displayed as a result of adhesive
recognition.
This can be reflected on the production
data in comparison to the set data.
NPM-W2 EJM7DE-MB-06O-00
6-2-14-3
Dummy dispensing
teach 2 (dispensing head)
Produc-
tion data
teaching
Operating procedure
6-2-14
1
Set a PCB on the PCB entrance
2
+
(The PCB is loaded and the head
camera moves to the dummy
dispensing position.)
2
Only when dummy dispensing is
carried out on a PCB.
3A
3
A
Lamp value adjustment button
When the lamp value is set to be
adjusted automatically, this step is not
necessary.
4B
4
B
Area size change button
Manually set the recognition search area.