N7201A616E00_0317 - 第622页
NPM-W 2 EJM7DE-MB-07 O-00 Machine parame- ter Operating procedure 7-3-10 7-3-10 A A Camer a of f set c hec k (inspection head) You can check the camera offset value (calibrati on result) in X and Y-axis by the inspection…

NPM-W2 EJM7DE-MB-07O-00
You can check the coefficient to apply the placement load of the head set in Load teaching
(→[Maintenance] P. 13-8-1).
●It is available only for 3-nozzle head.
7-3-9
Machine
parame-
ter
Head placement load
coefficient check
A
B
Operating procedure
7-3-9
Load coef
Load coefficients A and B per nozzle
position.
Stroke end
Stroke end per nozzle position.
AB
System
administration

NPM-W2 EJM7DE-MB-07O-00
Machine
parame-
ter
Operating procedure
7-3-10
7-3-10
A
A
Camera offset check
(inspection head)
You can check the camera offset value (calibration result) in X and Y-axis by the inspection head.
Offset
Camera offset values in X, Y and θ
directions.

NPM-W2 EJM7DE-MB-07O-00
Machine
parame-
ter
Operating procedure
7-3-11
7-3-11
A
A
B C
B
C
Shading offset
Corrects brightness of the inspection
area to be even.
White balance
Registers the adjusted color tone of the
inspection area.
Head camera
information check
(inspection head)
You can check the offset value (calibration result) of the inspection head camera unit.
Distortion offset
Corrects light distorted inner or outer
side through a lens
System