NPM-W 2 EJM7DE-MB-09O -00 9-1-1 -14 At a glance

NPM-W2 EJM7DE-MB-09O-00
9-1-1-13
Specifi-
cation
Machine specifications/
Basic performance 7
Operating procedure
9-1-1
Dispensing head specification (option)
Item Description
Dispensing direction
(angle)
-180° to 180° (in increments of 0.01°)
●Fixed at 0° for dummy
Dispensing range Conforming to the placement head
*1)
PCB flow direction Conforming to the placement head
Available nozzle count Up to 2 types
Dispensing tact time 0.16 s/dot (under optimum conditions)
Dispensing position repeat
accuracy
±0.075 mm (Cpk≧1.0)
Drawing tact time 3.75 s / Part (at the optimum condition)
Drawing position accuracy
±0.1 mm (Cpk≧1.0)
Temperature adjustment Heater
Dispensing pressure Programmable with the electropneumatic regulator
PCB changing time Conforming to the placement head
Adhesive ADE850D (recommended)
*2)
, ADE820DX (recommended)
*2)
Applicable component 1608 chip to SOP,PLCC,QFP,Connector,BGA,CPS
Dummy dispensing unit Standard equipment
Nozzle type
*3)
1-point nozzle
*4)
, 2-point nozzle, 4-point nozzle
Remaining amount
detection
After the detection of empty, stop or warning at the timing of arbitrary
dispensing
Such as solder apply, silver paste apply, and corner adhesive apply need technical confirmation.
1
) The value may vary by the anti-dispensing-on-rail function.
2
) For another maker, please consult us.
3
) As for the dispensing nozzle, there may be some changes.
4
) 1-point nozzle has two types of nozzles (dot dispensing and drawing dispensing)

NPM-W2 EJM7DE-MB-09O-00
9-1-1-14
At
a glance

NPM-W2 EJM7DE-MB-09O-00
Specifi-
cation
9-1-2-1
PCB flow direction
Single conveyor
●The PCB flow direction can be changed as option.
PCB flow
Movable rail
Fixed rail
Front
Left-to-right flow, Front reference
Movable rail
Fixed rail
Front
Right-to-left flow, Front reference
PCB flow
PCB flow
Movable rail
Fixed rail
Front
Left-to-right flow, Rear reference
Front
PCB flow
Right-to-left flow, Rear reference
Movable rail
Fixed rail
■Standard
■Option
1 2
1 2
Operating procedure
9-1-2