00192169-01 - 第30页

Order No. 00192 169-01 User Manual - Productivity Lift E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 30 6.4 Wait period PCB Time buffer for transferring a printed circuit board. Onc…

100%1 / 110
Order No. 00192 169-01 User Manual - Productivity Lift
E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 29
6.2 Interface 1
Interface 1 defines the interface at the inlet (n-1) to previous systems.
The available settings are SMEMA and Siemens.
N.B.
The device is equipped with a defined interface. The interface shown in the display must
conform to the interface installed at the interface module AMI 2-x. It's possible to change the
interface subsequently, but this may only be done by an authorised person.
Hand
Stop
Start
Enter
Alt
Figure 24: Interface 1
6.3 Interface 2
Interface 2 defines the interface at the outlet (n+1) to subsequent systems.
The available settings are SMEMA and Siemens.
N.B.
The device is equipped with a defined interface. The interface shown in the display must
conform to the interface installed at the interface module AMI 2-x. It is possible to change the
interface subsequently, but this may only be done by an authorised person.
Hand
Stop
Start
Enter
Alt
Figure 25: Interface 2
Interface 1
Siemens
Interface 2
Siemens
Order No. 00192 169-01 User Manual - Productivity Lift
E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 30
6.4 Wait period PCB
Time buffer for transferring a printed circuit board. Once this period has elapsed, the belt drive
is switched off and a fault indication is output since no PCB has arrived at the light barrier.
The unit of value is [0.01s] and the setting range is between 300 and 9999, which corresponds
to a time of 3 s to 99.99 s.
Hand
Stop
Start
Enter
Alt
Figure 26: Wait period PCB
6.5 Max. time un-belt
If a PCB has not been transferred from the conveyor to the lift after the adjusted time, the
automatic operating mode is stopped and the error signal shows PCB annuated. The PCB is
only then transferred from the conveyor to the following lift when the error signal is confirmed
with the Enter cursor through the user.
The unit of the value is [s] and the adjustment area is 0s to 9999s, whereas the function is
switched off for the value 0s.
Hand
Stop
Start
Enter
Alt
Figure 27: Max. time un-belt
Wait period PCB
2000
Max. time un-belt
0
Order No. 00192 169-01 User Manual - Productivity Lift
E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 31
6.6 Max. time lift 2
If the ramp up mode setting is 1 to 0, a PCP can be buffered on track 3 until the transport on
track 1 or track 2 is available again. The selected time defines the waiting period. If the
selected time is exceeded, the PCP is transfered to the buffer on track 3 of the underfloor
conveyor . Depending on the availability of track 1 and 2 the PCP is transported reverse into
the Productivity Lift for further processing.
The dimension is in [s]. The setting range is between 0  600 s.
The feature is turned off by entering 0.
Hand
Stop
Start
Enter
Alt
Figure 28: Max. time lift 2
6.7 Code number
N.B.
All the settings after this menu affect the basic parameters of the device and are generally only
defined during initial installation. For this reason, access is protected by code number entry.
The code number requested in the configuration may only be known to one authorised person,
and may not be passed on to unauthorised persons.
Hand
Stop
Start
Enter
Alt
Figure 29: Code number
Code number
0000
Max. time Lift 2
000