Order No. 00192 169-01 User Manual - Productivity Lift E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 33 6.11 Lead adjusting 1 This menu can be used to set the mode for operation of …

Order No. 00192 169-01 User Manual - Productivity Lift
E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 32
6.8 Underneath belt
If the lift is installed as the end module in the line, it no longer has an underfloor conveyor.
This function must then be disabled in this menu.
Hand
Stop
Start
Enter
Alt
Figure 30: Underneath belt
6.9 Conveyors on LF1
Depending on the revision level of the Productivity Lift, the Top Conveyor, has one or two
conveyors. Select the appropriate setting 1 or 2. 1 for one conveyor. 2 for two
conveyors.
Hand
Stop
Start
Enter
Alt
Figure 31: Conveyors on LF1
6.10 ALT protection
With this function (adjustment switched on) the input possibilities in the configuration menu
(t and Alt cursor) and in the adjustment modus (Alt cursor) are locked. Input is only
possible when the interlock is used.
Hand
Stop
Start
Enter
Alt
Figure 32: ALT protection
Underneath belt
turned off
ALT protection
turned on
Conveyor on LF 1
1

Order No. 00192 169-01 User Manual - Productivity Lift
E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 33
6.11 Lead adjusting 1
This menu can be used to set the mode for operation of the automatic tracking facility (option)
for width adjustment for the lift belt top. The following are possible:
turned off : The device has no electrical width adjustment (standard).
manual : The device has an electrical width adjustment facility but no automatic tracking
facility. The width must be adjusted in the manual-operating mode using the
corresponding function.
automatic : The device has an automatic tracking facility. This setting is then used to
constantly check the transport width of the device, which prescribes the width.
only at start : The device has an automatic tracking facility. This setting is then used to check
the transport width of the device, which prescribes the width, but only at the
start of the lift.
Hand
Stop
Start
Enter
Alt
Figure 33: Lead adjusting 1
6.12 Lead adjusting 2
This menu has to be used to set the mode for operation of the automatic tracking facility for
width adjustment for the shuttle. The following are possible:
manual : The device has an electrical width adjustment facility but no automatic tracking
facility. The width must be adjusted in the manual-operating mode using the
corresponding function.
automatic : The device has an automatic tracking facility. This setting is then used to
constantly check the transport width of the device, which prescribes the width.
only at start : The device has an automatic tracking facility. This setting is then used to check
the transport width of the device, which prescribes the width, but only at the
start of the lift.
Hand
Stop
Start
Enter
Alt
Figure 34: Lead adjusting 2
Lead adjusting 1
manual
Lead adjusting 2
manual

Order No. 00192 169-01 User Manual - Productivity Lift
E_SPLFS03_V40_11_0300_200300_V1_14.doc Last update: 20.03.2000 - Version V 1.14 Page 34
6.13 Lead adjusting 3
This menu has to be used to set the mode for operation of the automatic tracking facility for
width adjustment of the Underfloor Conveyor. The following are possible:
manual : The device has an electrical width adjustment facility but no automatic tracking
facility. The width must be adjusted in the manual-operating mode using the
corresponding function.
automatic : The device has an automatic tracking facility. This setting is then used to
constantly check the transport width of the device, which prescribes the width.
only at start : The device has an automatic tracking facility. This setting is then used to check
the transport width of the device, which prescribes the width, but only at the
start of the lift.
Hand
Stop
Start
Enter
Alt
Figure 35: Lead adjusting 3
6.14 Address width 1 / Address width 2 Option
This function is optional. It allows an automatic width adjustment of the Productivity Lifts within
a line configuration.
This menu is not active, if this option is available and Lead adjusting 1 and Lead adjusting 2
(chapter 6.11 and 6.12) has been set to manual.
The width setting of the Siplace Placement units is mandatory for the width setting of the
Productivity Lifts.
To enable the automatic width setting, there are certain line configuration settings required.
It is required, that there is a CAN-BUS featured module in front of the input module and a
Siplace placement unit behind the output module. The Siplace unit must be followed by a
CAN-BUS featured module.
The module before the input module (n-1) has address 1. This address is used to verify the
width. The module after the last placement machine (n+1) owns address 2. The requested
data from this module are used to set the width. The width of the Productivity Lifts in such a
line is changed only when all Siplace Placement units between input and output module carry
no PCB. The module (n+1) detects the new width setting at the last placement unit, using a
sensor. The new width setting is transmitted via CAN-BUS to the Productivity Lifts in the line.
Other settings are also possible e.g. module with address 1 is also addressed as module 2.
With this setting module (n-1) is used to verify and to transmit the width setting to the other
Productivity lifts.
The set up for this option must be performed by a qualified Service engineer.
NOTE
This setting has to be conducted by a Service engineer of the equipment manufacturer or
needs to be approved by Service engineer of the equipment manufacturer !
Lead adjusting 3
manual