3 Mechanical Section 3-5 ■ Checkin g of Suction Pad (for n ozzle No. M017, M 018, M 019, M020) Check the rubber su ction pad at the tip of th e nozzle for f laws and cracks. If you f ind a flaw or crack, replace the pad …

100%1 / 48
3 Mechanical Section
3-4
Nozzle Cleaner
Assy.
Move the nozzle back and forth to clean the nozzle hole.
Never forget to blow some air into the nozzle hole.
Nozzle Cleaning using Wire (2)
You can use the wire by fastening the wire ends with adhesive tape. In this case, adhesive may remain on the
wire. So be sure to clean the wire end before pulling out the wire form the nozzle.
Adhesive Tape
3 Mechanical Section
3-5
Checking of Suction Pad (for nozzle No. M017, M018, M019, M020)
Check the rubber suction pad at the tip of the nozzle for flaws and cracks. If you find a flaw or crack, replace
the pad with a new one.
First, pull off the old pad, and then apply some grease to the inner surface of the new pad to fit it to the
nozzle.
Apply silicone grease.
Identification Mark
Suction Pad
Applying Silicone Grease
After cleaning a nozzle, be sure to apply grease to the nozzle.
Outer Surface
Apply small amount of silicone grease to the outer surface (indicated by thick dotted line). And then wipe
off the grease with a dry cloth to make a very thin film of grease.
Suction Pad
Use grease to prevent the rubber suction pad from degrading. Apply small amount of silicone grease to the
outer surface of the pad. And then wipe off the grease with a dry cloth.
Do not apply excessive grease, which may cause the nozzle to clog with dirt
and result in the placement error.
3 Mechanical Section
3-6
Nozzle Recognition Stickers
Labeling a Nozzle ID Sticker to a Nozzle
ACTION:
Wipe off oil, dust, or water from the upper side of the nozzle flange with alcohol.
Slide the ring of the labeler until the groove in the labeler shaft appears.
Peel off the sticker from its slip sheet using tweezers.
With the stickers adhesive side upward, align the stickers angle mark to the rings positioning mark.
Set the sticker into the ring, being careful not to touch the stickers adhesive side.
Make sure the sticker is properly placed in the ring.
Insert the nozzle upside down into the hollow of the labeler shaft, while aligning the nozzle cutoff to the
rings positioning mark.
Push up the labeler shaft so that the sticker sticks to the nozzle flange.
Nozzle
Cutoff
Nozzle ID sticker
Positioning mark
Ring
Groove
Shaft
Labeler for
nozzle ID sticker
Angle mark