DFD6361-Maintenance - 第211页
B-139 Procedures for adjusting utilities of spinn er atomizing nozz le (Continued) St e p N o . Do This 3 Whil e checking the pures sure gauge o f clean ai r , t urn the adjustment knob to adjust the pressure to approxim…

B-138
Procedures for adjusting utilities of spinner atomizing nozzle
Step No. Do This
1
Remove the cover [U]. The store it sufficiently away from the
working area.
[U]
LEFT SIDE
2
Using the I/O CHECK screen, discharge the mixed fluid of clean
air and cleaning water from the spinner atomizing nozzle.
- For I/O CHECK screen;
See the section C-4-1, [I/O Check].

B-139
Procedures for adjusting utilities of spinner atomizing nozzle (Continued)
Step No. Do This
3
While checking the puressure gauge of clean air, turn the
adjustment knob to adjust the pressure to approximately 0.4MPa.
ÿ
Increase
Decrease
Air pressure adjustment knob for spinner atomizing
nozzle clean air [Optional accessory]
Air pressure sensor for
spinner atomizing nozzle
clean air
[Optional accessory]
4
While checking the flowmeter of cleaning water, turn the
adjustment knob to adjust the flow rate to approximately
200 ml/min.
Increase
Decrease
Spinner atomizing nozzle cleaning water
flowmeter [Optional accessory]
Spinner atomizing nozzle cleaning water
adjustment knob [Optional accessory]
5
Using the I/O CHECK screen, stop discharge of the mixed fluid
of clean air and cleaning water from the spinner atomizing
nozzle.
6
Reinstall the cover [U].

B-140
Procedures for setting monitor value of clean air pressure for spinner atomizing nozzle
(Continued)
Step No. Do This
1
Press the <F6> button on the MAIN MENU screen [screen 0.0].
- PASSWORD screen is called up.
2
Type the user password and press the <ENTER> button.
- The MACHINE MAINTENANCE screen [screen 6.0] is called
up.
3
Press the <F6> button on the MACHINE MAINTENANCE
screen [screen 6.0].
- The SENSOR THRESHOLD DATA screen [screen 6.6] is
called up.
4
Set "0.200MPa" as the lower limit of atomizing clean air (N
2
)
pressure, and then press the <ENTER> button.
- The machine updates the data.