DFD6361-Maintenance - 第337页
D-52 B0562 : Z 1-axi s at blade expos ure limit . Error c ode B0562 Message Z1- axis at blade expo sure li mit. W hat wa s detected The value of [work piece th ickness - Z1-axis blad e heigh t (cut depth) ] was greater t…

D-51
B0031 : Setup data error.
Error code
B0031
Message
Setup data error.
What was
detected
An attempt was made to initiate cutting although the setup process was not
completed.
During what
operation it
occurred
At the beginning of cutting.
State after
detection
No cutting operation can be initiated.
Phenomenon Probable causes Remedy Reference
What to do
An error occurred
when the power
was turned ON, and
for that reason, the
last setup data was
erased.
The battery of the
CPU board may be
exhausted.
1. Conduct setup.
2. The battery will
be charged by
about 70-hour
normal operation.
If the error still
occurs frequently,
the battery is at the
end of its life.
Contact your
nearest Disco
Service Office.
Recovery
(1) Cancel the alarm.
(2) Cancel the cutting operation and perform the setup process.
(3) After the setup process is normally ended, resume the cutting operation.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear

D-52
B0562 : Z1-axis at blade exposure limit.
Error code
B0562
Message
Z1-axis at blade exposure limit.
What was
detected
The value of [workpiece thickness - Z1-axis blade height (cut depth)] was
greater than the [current Z1-axis blade tip protrusion amount - (workpiece
thickness - Z1-axis blade height + clearance)].
During what
operation it
occurred
Before cutting.
State after
detection
No cutting operation can be started.
Phenomenon Probable causes Remedy Reference
What to do
Recovery
(1) Cancel the alarm.
(2) Replace the blade.
(If cutting needs to be continued, you can cut a single workpiece by
pressing the <START> button. However, the error recurs upon
completion of cutting to issue a warning.)
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear

D-53
B0563 : Z2-axis at blade exposure limit.
Error code
B0563
Message
Z2-axis at blade exposure limit.
What was
detected
The [workpiece thickness - Z2-axis blade height (cut depth)] was greater
than the [current Z2-axis blade tip protrusion amount - (workpiece thickness
- Z2-axis blade height + clearance)].
During what
operation it
occurred
Before cutting.
State after
detection
No cutting operation can be started.
Phenomenon Probable causes Remedy Reference
What to do
Recovery
(1) Cancel the alarm.
(2) Replace the blade.
(If cutting needs to be continued, you can cut a single workpiece by
pressing the <START> button. However, the error recurs upon
completion of cutting to issue a warning.)
Maintenance level Maintenance personnel level Hazard level