DFD6361-Maintenance - 第341页
D-56 B0582 : Z 1-axis c alibrate sensor. Error c ode B0582 Option al accesso ry Message Z1- axis calibrate sensor. W hat wa s detected Sensor calib ration setup was not completed before Z1- axis non- contact setup pro ce…

D-55
B0565 : Z2-axis at blade life limit.
Error code
B0565
Message
Z2-axis at blade life limit.
What was
detected
The length or counts of cut lines has reached the Z2-axis blade use limit
defined on the BLADE REPLACEMENT screen [screen 4.1].
During what
operation it
occurred
During the Z2-axis cutting.
State after
detection
The cutting operation is discontinued.
Phenomenon Probable causes Remedy Reference
What to do
Recovery
(1) Cancel the alarm.
(2) Replace the Z2-axis blade.
(If cutting needs to be continued, you can cut a single workpiece by
pressing the <START> button. However, the error recurs upon
completion of cutting to issue a warning.)
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear

D-56
B0582 : Z1-axis calibrate sensor.
Error code
B0582
Optional accessory
Message
Z1-axis calibrate sensor.
What was
detected
Sensor calibration setup was not completed before Z1-axis non-contact
setup process initiation.
During what
operation it
occurred
At the beginning of Z1-axis non-contact setup.
State after
detection
The Z1-axis non-contact setup process is discontinued.
Phenomenon Probable causes Remedy Reference
What to do
Recovery
(1) Cancel the alarm.
(2) Execute sensor calibration setup.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear

D-57
B0583 : Z1-axis setup error (error detection.)
Error code
B0583
Message
Z1-axis setup error (error detection.)
What was
detected
The Z1-axis setup operation ended within the Z-axis high-speed movement
range.
During what
operation it
occurred
During Z1-axis setup operation.
State after
detection
The setup operation ends after the Z1-axis returns to its origin.
Setup data value registration does not take place.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
Erroneous detection
occurs during setup
operation due to
water drops on the
setup position
section.
Increase the setup
data value for the
setup blow time
setting.
With an air-
injection gun,
remove water drops
from the table
upper surface and
spindle section.
Recovery
(1) Cancel the alarm.
(2) Select the setup operation again.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear