DFD6361-Maintenance - 第347页

D-62 B0588 : Z 1-axi s setup data error . Error c ode B0588 Message Z1- axis setup da ta erro r. W hat wa s detected An att empt was made to i nitiate cutting with the Z1-axis a lthoug h the Z1- axis se tup process w as …

100%1 / 720
D-61
B0587 : Z1-axis blade wear check error.
Error code
B0587
Message
Z1-axis blade wear check error.
What was
detected
The Z1-axis setup data for the blade wear check limit value was exceeded
by the difference between the current and previous setup values.
During what
operation it
occurred
After Z1-axis setup operation.
State after
detection
Setup data value registration does not take place.
Phenomenon Probable causes Remedy Reference
What to do
The error recurs
when setup is
attempted again.
Erroneous detection
occurs during setup
operation due to
water drops on the
setup position
section.
Increase the setup
data value for the
setup blow time
setting.
The non-contact
setup sensor is
soiled.
Clean the non-
contact setup
sensor.
The setup data value
for the Z1-axis blade
wear check limit
setting is too small.
Enter a limit setting
appropriate for the
Z1-axis blade wear
amount.
Recovery
(1) Cancel the alarm.
(2) Perform the customer-defined procedure for excessive blade wear.
(3) Perform the setup operation again.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear
D-62
B0588 : Z1-axis setup data error.
Error code
B0588
Message
Z1-axis setup data error.
What was
detected
An attempt was made to initiate cutting with the Z1-axis although the Z1-
axis setup process was not completed.
During what
operation it
occurred
At the beginning of Z1-axis cutting.
State after
detection
No cutting operation can be initiated using the Z1-axis.
Phenomenon Probable causes Remedy Reference
What to do
Recovery
(1) Cancel the alarm.
(2) Cancel the cutting operation and perform the Z1-axis setup process.
(3) After the Z1-axis setup process is normally ended, resume the cutting
operation.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear
D-63
B0589 : Z2-axis calibrate sensor.
Error code
B0589
Optional accessory
Message
Z2-axis calibrate sensor.
What was
detected
Sensor calibration setup was not completed before Z2-axis non-contact
setup process initiation.
During what
operation it
occurred
At the beginning of Z2-axis non-contact setup.
State after
detection
The Z2-axis non-contact setup process is discontinued.
Phenomenon Probable causes Remedy Reference
What to do
Recovery
(1) Cancel the alarm.
(2) Execute sensor calibration setup.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear