DFD6361-Maintenance - 第348页

D-63 B0589 : Z 2-axis c alibrate sensor. Error c ode B0589 Option al accesso ry Message Z2- axis calibrate sensor. W hat wa s detected Sensor calib ration setup was not completed before Z2- axis non- contact setup pro ce…

100%1 / 720
D-62
B0588 : Z1-axis setup data error.
Error code
B0588
Message
Z1-axis setup data error.
What was
detected
An attempt was made to initiate cutting with the Z1-axis although the Z1-
axis setup process was not completed.
During what
operation it
occurred
At the beginning of Z1-axis cutting.
State after
detection
No cutting operation can be initiated using the Z1-axis.
Phenomenon Probable causes Remedy Reference
What to do
Recovery
(1) Cancel the alarm.
(2) Cancel the cutting operation and perform the Z1-axis setup process.
(3) After the Z1-axis setup process is normally ended, resume the cutting
operation.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear
D-63
B0589 : Z2-axis calibrate sensor.
Error code
B0589
Optional accessory
Message
Z2-axis calibrate sensor.
What was
detected
Sensor calibration setup was not completed before Z2-axis non-contact
setup process initiation.
During what
operation it
occurred
At the beginning of Z2-axis non-contact setup.
State after
detection
The Z2-axis non-contact setup process is discontinued.
Phenomenon Probable causes Remedy Reference
What to do
Recovery
(1) Cancel the alarm.
(2) Execute sensor calibration setup.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear
D-64
B0590 : Z2-axis setup error (error detection.)
Error code
B0590
Message
Z2-axis setup error (error detection.)
What was
detected
The Z2-axis setup operation ended within the Z-axis high-speed movement
range.
During what
operation it
occurred
During Z2-axis setup operation.
State after
detection
The setup operation ends after the Z2-axis returns to its origin.
Setup data value registration does not take place.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
Erroneous detection
occurs during setup
operation due to
water drops on the
setup position
section.
Increase the setup
data value for the
setup blow time
setting.
With an air-
injection gun,
remove water drops
from the table
upper surface and
spindle section.
Recovery
(1) Cancel the alarm.
(2) Select the setup operation again.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear