DFD6361-Maintenance - 第350页
D-65 B0591 : Z 2-axis s etup error ( Z-axis position er ror.) Error c ode B0591 Message Z2- axis setup error (Z-axis position er ror.) W hat wa s detected The Z 2-axis did not operate in Z2-axis s etup pro cess. During w…

D-64
B0590 : Z2-axis setup error (error detection.)
Error code
B0590
Message
Z2-axis setup error (error detection.)
What was
detected
The Z2-axis setup operation ended within the Z-axis high-speed movement
range.
During what
operation it
occurred
During Z2-axis setup operation.
State after
detection
The setup operation ends after the Z2-axis returns to its origin.
Setup data value registration does not take place.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
Erroneous detection
occurs during setup
operation due to
water drops on the
setup position
section.
Increase the setup
data value for the
setup blow time
setting.
With an air-
injection gun,
remove water drops
from the table
upper surface and
spindle section.
Recovery
(1) Cancel the alarm.
(2) Select the setup operation again.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear

D-65
B0591 : Z2-axis setup error (Z-axis position error.)
Error code
B0591
Message
Z2-axis setup error (Z-axis position error.)
What was
detected
The Z2-axis did not operate in Z2-axis setup process.
During what
operation it
occurred
During Z2-axis setup operation.
State after
detection
The Z2-axis returns to its origin and the setup operation terminates.
Setup data value registration does not take place.
Phenomenon Probable causes Remedy Reference
What to do
The error recurs
even when setup is
attempted again.
The setup wiring
between
the SETUP board
and Z-axis driver is
broken.
Contact your
nearest DISCO
Service Office.
Recovery
(1) Cancel the alarm.
(2) Select the setup operation again.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear

D-66
B0592 : Z2-axis setup error (No detection.)
Error code
B0592
Message
Z2-axis setup error (No detection.)
What was
detected
Setup was not completed when the Z2-axis has reached the software defined
lower-end.
During what
operation it
occurred
During Z2-axis setup operation.
State after
detection
The Z2-axis returns to its origin and the setup operation terminates.
Setup data value registration does not take place.
Phenomenon Probable causes Remedy Reference
What to do
The error recurs
when setup is
attempted again.
The Z2-axis blade
outside diameter
entry is incorrect.
Correct the Z2-axis
blade outside
diameter value
entered from the
BLADE
REPLACEMENT
screen [screen 4.1].
The servicing maker
data is improper.
Contact your
nearest DISCO
Service Office.
Recovery
(1) Cancel the alarm.
(2) Select the setup operation again.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear