DFD6361-Maintenance - 第420页

D-135 X ••• 0: -axis unrecoverabl e error. R estart t he mac hine. Error c ode X ••• 0 Message -axis unrecoverable erro r. Restart the machine. W hat wa s detected The C PU in the -axis motor con troller fa iled to wo rk…

100%1 / 720
D-134
X0010 : Y-axis scale error......Reinitialize.
Error code
X0010
Message
Y-axis scale error......Reinitialize.
What was
detected
The machine could not recognize the Y-axis position.
During what
operation it
occurred
At any time during axis operation.
State after
detection
Allaxescometoanimmediatestop.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
The motor control
circuit board is
defective.
Contact your
nearest DISCO
Service Office.
The axis is broken. Contact your
nearest DISCO
Service Office.
When executing the
non-contact setup,
the setup position
cannot be found.
The maker data
problem.
Contact your
nearest DISCO
Service Office.
Recovery
(1) Cancel the alarm.
(2) Effect system initialization.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear
D-135
X•••0: -axis unrecoverable error. Restart the machine.
Error code
X•••0
Message
-axis unrecoverable error. Restart the machine.
What was
detected
The CPU in the
-axis motor controller failed to work properly due to
noise or some other factor.
During what
operation it
occurred
At any time during axis operation.
State after
detection
Allaxescometoanimmediatestop.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
Poor contact between
the connectors and
circuit board.
Re-insert the circuit
board.
Contact your
nearest DISCO
Service Office.
The motor control
circuit board is
defective.
Contact your
nearest DISCO
Service Office.
Recovery
(1) Cancel the alarm.
(2) Turn OFF the machine power.
(3) Wait more than one minute and turn the power back ON.
(4) Effect system initialization.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear
D-136
X•••1: -axis unknown error.(…..Reinitialize.)
Error code
X•••1
Message
-axis unknown error.(…..Reinitialize.)
What was
detected
No operation signal returned from the motor control board side, when CPU
sent an axis operation instruction.
During what
operation it
occurred
At any time during axis operation.
State after
detection
Allaxescometoanimmediatestop.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
Poor contact between
the connectors and
circuit board.
Re-insert the circuit
board.
Contact your
nearest DISCO
Service Office.
The motor control
circuit board is
defective.
Contact your
nearest DISCO
Service Office.
Recovery
(1) Cancel the alarm
(2) Effect system initialization.
Maintenance level Maintenance personnel level Hazard level