DFD6361-Maintenance - 第424页

D-139 X ••• 4: -axis CCW end error.(… ..Reinitializ e.) Error c ode X ••• 4 Message -axis CCW end error.(…..R einitialize.) W hat wa s detected Th ere was a n in put to t he -axis CC W end sen sor. During what operation …

100%1 / 720
D-138
X•••3: -axis CW end error.(…..Reinitialize.)
Error code
X•••3
Message
-axis CW end error.(…..Reinitialize.)
What was
detected
There was an input signal to the
-axis CW end sensor.
During what
operation it
occurred
At any time during axis operation.
State after
detection
Allaxescometoanimmediatestop.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
The CW end sensor
is displaced.
Contact your
nearest DISCO
Service Office.
The maker data for
the origin position
setting is incorrect.
Contact your
nearest DISCO
Service Office.
Recovery
(1) Cancel the alarm.
(2) Effect system initialization.
(3) Set the operation prior to the error occurrence, and execute it again.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear
D-139
X•••4: -axis CCW end error.(…..Reinitialize.)
Error code
X•••4
Message
-axis CCW end error.(…..Reinitialize.)
What was
detected
There was an input to the
-axis CCW end sensor.
During what
operation it
occurred
At any time during axis operation.
State after
detection
Allaxescometoanimmediatestop.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
The CCW end sensor
is displaced.
Contact your
nearest DISCO
Service Office.
The maker data for
the origin position
setting is incorrect.
Contact your
nearest DISCO
Service Office.
Recovery
(1) Cancel the alarm.
(2) Effect system initialization.
(3) Set the operation prior to the error occurrence, and execute it again.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear
D-140
X•••5: -axis vibration error (near).(…..Reinitialize.)
Error code
X•••5
Message
-axis vibration error (near).(…..Reinitialize.)
What was
detected
The axis vibration is large.
During what
operation it
occurred
At any time during axis operation.
State after
detection
Allaxescometoanimmediatestop.
Phenomenon Probable causes Remedy Reference
What to do
Loud sound comes
out during the
spindle axis
rotation (Y-axis).
The flange is
improperly balanced.
Contract your
nearest DISCO
Service Office.
The error occurs
frequently.
The maker data setup
for the axis
parameter data is
improper.
Contact your
nearest DISCO
Service Office.
Recovery
(1) Cancel the alarm.
(2) Effect system initialization.
(3) Set the operation prior to the error occurrence, and execute it again.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear