DFD6361-Maintenance - 第437页

E-1 E. MAINTENANCE AND PERIODIC INSPECTION Cont ents of t his ch apter This chapter exp lains maintenance and i nspection required for the machine b y the interval period. Section No. Titl e Contents Cleaning the Non-Con…

100%1 / 720
D-151
O1036 : Inspection cassette switch turned OFF.
Error code
O1036
Message
Inspection cassette switch turned OFF.
What was
detected
This error occurs if the inspection cassette presence/absence sensor
mounted on the inspection cassette stage receives OFF signal.
During what
operation it
occurred
During the full automatic operation and while the elevator is moving.
State after
detection
The elevator operation stops.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
although the
cassette is placed
properly.
The sensor is
defective.
Replace the sensor.
Recovery
(1) Cancel the alarm, then the ERROR RECOVERY (HANDLING) screen
is displayed.
(2) Set the cassette to the elevator again.
(3) Perform the error recovery steps indicated on the screen.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear
E-1
E. MAINTENANCE
AND PERIODIC INSPECTION
Contents of this chapter
This chapter explains maintenance and inspection required for the machine by
the interval period.
Section
No.
Title Contents
Cleaning the Non-Contact setup sensor
Cleaning the blade breakage detector
sensor
Cleaning the spindle
1
Maintenance Whose
Interval Differs
Depending on the Machine Use
Conditions
Cleaning the touch panel
Checking stains on the safety labels
Checking the air spindle axis rotation
Checking the scratches and soiling on
the flange
Checking the soiling and damage on
the chuck table
Checking that the work being taken
over properly
Checking the air supply pressure
Checking the abnormal noise or
vibration produced by the spindle
during rotation
Checking the splash cover and arm
section cover status during spindle
rotation
Checking the splash cover and arm
section cover status during the spinner
table rotation
Checking Z EM sequence
Checking EMO switch activation
2
Maintenance and Inspection
to Be Done
Every Day
Checking the spinner high-pressure
pump pressure
Cleaning the cutting room
3
Maintenance to Be Performed at
7-Day Intervals
(Recommended)
Flange conditioning
4
Maintenance to Be Performed at
30-Day Intervals
(Recommended)
E-2
Contents of this chapter (Continued)
Section
No.
Title Contents
Wheel mount conditioning
Greasing the elevator axis
Greasing the frame centering axis
5
Maintenance to Be Performed at
183-Day Intervals
(Recommended)
Cleaning the spindle coolant water
path
Cleaning the vacuum ejector
Greasing the X-axis
Greasing the push-pull axis
Greasing the upper arm axis
Greasing the lower arm axis
Greasing the θ-axis sensor assembly
section
Greasing the Y (Y1 and Y2) -axis
6
Maintenance to Be Performed at
365-Day Intervals
(Recommended)
Greasing the Z (Z1 and Z2) -axis