DFD6361-Maintenance - 第460页
E-24 Position o f the ampl ifier of bl ade break age detector The illustration below shows the location of the amplifier of bla de breakage detector. Z1-axis Z2-axis Amplif ier Amplif ier

E-23
1-2-3. Adjusting the amplifier of blade breakage detector
The case where this procedure is required
This adjustment become necessary when the maximum sensitivity does not
come between or equal to 90% and 99%, even after cleaning the sensor section
of the blade breakage detector.
Operation flow
The procedure for adjusting the amplifier of blade breakage detector consists
of the following steps.
1-2-3-1 Moving the Y (Y1, Y2)-axis
1-2-3-2 Removing the partition (left)
1-2-3-3. Adjusting the amplifier of blade breakage detector
Before adjustment
Have on hand the following tool to adjust the blade breakage detector
amplifier.
Tool Part No.
Amplifier adjustment driver
AK81526287
-Others;
3mm Allen wrench
Phillips screwdriver

E-24
Position of the amplifier of blade breakage detector
The illustration below shows the location of the amplifier of blade breakage
detector.
Z1-axis Z2-axis
Amplifier Amplifier

E-25
Safety items for adjusting the amplifier of blade breakage detector
WARNING
- This procedure requires you to put your hand into the drive section,
where your hand or fingers could be caught or cut off.
During this operation, allow no one else to touch the machine.
- If you keep the splash cover closed after moving the axes, you have
to perform the adjustment operation with the interlock system
released. Since there is a driving section near your working section,
if the interlock system is canceled, your hands or arms may be
caught or amputated due to unexpected machine operation.
After you move the axes, be sure to open the splash cover in order
to activate the interlock of the cover.
CAUTION
When you perform maintenance with the partition removed, observe
the following precaution. If you stand the removed partition against
the machine, you may receive injury by the partition if it is toppled by
the earthquake or like that.
After taking off the partition for maintenance purposes, store it
sufficiently away from the working area.
CAUTION
If you don't use the amplifier adjustment driver designed specifically
for this use when you turn the sensitivity regulation dial, the dial may
be damaged or broken.
Ensure to use the amplifier adjustment driver (black resin).