E-52 5. Maintenance to Be Performed at 183-Day (Recommended) Intervals Summary of this sectio n This section describes the m aintenance to be done at 183-da y intervals. Section No. Titl e Contents 5-1 Conditioning the H…

100%1 / 720
E-51
4. Maintenance to Be Performed at 30-Day
(Recommended) Intervals
Summary of this section
This section describes the maintenance to be done at 30-day intervals.
Section No. Title Contents
4-1 Conditioning the Flange - Procedures for conditioning the
flange
4-1. Conditioning the Flange
Procedures for conditioning the flange
For the procedures to perform the flange conditioning, see the section C-2,
[Wheel Mount/Flange Conditioning] of the Maintenance Manual.
E-52
5. Maintenance to Be Performed at 183-Day
(Recommended) Intervals
Summary of this section
This section describes the maintenance to be done at 183-day intervals.
Section No. Title Contents
5-1 Conditioning the Hub
Mount
- Procedures for conditioning the
hub mount
5-2 Greasing the Elevator
Axis
- Procedures for greasing the
elevator axis
5-3 Greasing the Frame
Centering Axis
- Procedures for greasing the
frame centering axis
5-4 Cleaning the Spindle
Coolant Water Path
- Procedures for cleaning the
spindle coolant water path
5-1. Conditioning the Hub Mount
Procedures for conditioning the hub mount
For the procedures to perform the hub mount conditioning,
see the section C-2, [Hub Mount/Flange Conditioning].
E-53
5-2. Greasing the Elevator Axis
Operation flow
The procedure for greasing the elevator axis consists of the following steps.
5-2-1 Preparation of greasing the elevator axis
5-2-2 Greasing the elevator axis
5-2-3 Completion of greasing the elevator axis
Safety items for greasing the elevator axis
WARNING
If any touch panel control is inadvertently activated during
maintenance or inspection, unexpected machine operation may
cause death or serious injury.
While you don't use the touch panel, press the Disco's logo button
located at the upper left of the screen in order to lock up and
deactivate the touch panel.
CAUTION
When you perform maintenance with the outer cover removed,
observe the following precaution. If you stand the removed outer
cover against the machine, you may receive injury by the cover if it is
toppled by the earthquake or like that.
After taking off the outer cover for maintenance purposes, store it
sufficiently away from the working area.
CAUTION
If the axis does not move for a long time after being greased, the
grease will harden. This could adversely affect the precision of the
machine, such as a position error during axis operation.
Do not perform greasing before a long-term operation suspension.