F-31 1-5-1. Prep aration of replacing the spray tip Procedur es for prep aration of re placing th e spray tip W ARNING - In the di gital I/O check pr ocedures, touc h panel buttons except f or function b uttons ar e inop…

F-30
1-5. Replacing the Spray Tip of the Spinner Section
Operation flow
The procedure for replacing the spray tip of the spinner section nozzle axis
consists of the following steps.
Note that the spinner atomizing nozzle [optional accessory] has no
consumable parts.
1-5-1 Preparation of replacing the spray tip
1-5-2 Replacing the spray tip
1-5-3 Completion of replacing the spray tip
Before replacement
Have on hand the following items for replacing.
- Wrench

F-31
1-5-1. Preparation of replacing the spray tip
Procedures for preparation of replacing the spray tip
WARNING
- In the digital I/O check procedures, touch panel buttons except for
function buttons are inoperative.
Even if, for example, you press the <Cut Water> button, the wheel
coolant supply does not shut off.
The personnel who perform the digital I/O checkout must bear this
in mind and exercise due care to ensure safety.
- In the digital I/O check procedures, the operation command for
solenoid valves and etc. can be forcibly turned ON and OFF by the
function buttons. In some cases, therefore, a cylinder may be
invoked to operate.
Ensure that no person other than the maintenance personnel
touches the machine during this procedure.
- If any touch panel control is inadvertently activated during
maintenance or inspection, unexpected machine operation may
cause death or serious injury.
While you don't use the touch panel, press the Disco's logo button
located at the upper left of the screen in order to lock up and
deactivate the touch panel.
Step No. Do This
1
From the ENGINEERING MAINTENANCE screen [screen 7.0],
press the <F3> button.
- The I/O CHECK screen then appears.

F-32
Procedures for preparation of replacing the spray tip (Continued)
Step No. Do This
2
Select the DO for "S/T (spinner table) UP/DOWN" to lower the
spinner table.
3
From the ENGINEERING MAINTENANCE screen [screen 7.0],
press the <F2> button.
- The AXIS OPERATION screen [screen 7.2] then appears.
4
Select "NOZZLE" item and move the spinner nozzle to above the
spinner table by using the function button.
5
Turn OFF the main switch and pull out the key.
6
Turn OFF the circuit breaker at the left of the machine. Lock out
the circuit breaker lever with a padlock or the like.
7
Shut off the facility power supply.
Continued in the next section.