F-46 Procedur es for prep aration of re placing th e Y-ax is section roll c over (C ontinued) Step No. Do This 7 [ W hen t here is m aintenance sp ace prov ided at the r ear side of the m achine] Remove the cover [R]. [R…

F-45
1-8-1. Preparation of replacing the Y-axis section roll cover
Procedures for preparation of replacing the Y-axis section roll cover
Step No. Do This
1
Press the <System Initial> button to effect system initialization.
2 [When there is maintenance space provided at the rear
side of the machine]
With the button, move the Y1-axis until it stops at the
front end.
[When there is no maintenance space provided at the rear
side of the machine]
Go to the step No. 3.
3
Turn OFF the main switch and then pull out the key.
4
Turn OFF the circuit breaker and then lock out the circuit breaker
lever with a padlock or the like.
5
Shut off the facility power supply.
6
Close the facility main valve of air and spindle coolant water.

F-46
Procedures for preparation of replacing the Y-axis section roll cover (Continued)
Step No. Do This
7 [When there is maintenance space provided at the rear
side of the machine]
Remove the cover [R].
[R]
REAR SIDE
[When there is no maintenance space provided at the rear
side of the machine]
Go to the step No. 8.

F-47
Procedures for preparation of replacing the Y-axis section roll cover (Continued)
Step No. Do This
8
Remove the cover [A].
[P]
[A]
FRONT SIDE
9
Open the cover [P].
- For the opening procedures of the touch panel section outer
cover
See section A-1, [Machine Outer Cover].
10
Remove the partition (left). Then store it sufficiently away from
the working area.
- For the removal procedures of the partition (left);
See the section 1-2-3-2 of this chapter, [Removing the partition
(left)].
11
Store the removed covers and partition sufficiently away from
the working area.
Continued in the next section.