F-116 5-3-1. Shutting off po w er Procedur es for shut ting off pow er Step No. Do This 1 Press the <Sy stem Initial> button to effec t system initialization. - Each axis moves to its origin position. 2 Turn OFF th…

100%1 / 720
F-115
The usage limit of the UV irradiation lamp
Long-hours use of the UV irradiation unit will make the UV irradiation lamp,
in accordance with this, the irradiation power of the lamp will also decline.
You can calculate the usage limit of a UV irradiation lamp by the following
equation.
The usage limit of a UV irradiation lamp = 2000 hours ÷ (irradiation time
of one workpiece)
÷ (number of workpieces processed in a day)
When the UV irradiation lamp use period reaches the calculated value, replace
the UV irradiation lamp.
The number of the UV irradiation lamps mounted in the machine is ten. When
one of the lamps reaches its usage limit, replace all of them.
Operation flow
This section describes the procedure for replacing the UV irradiation lamp.
This procedure consists of the following steps:
5-3-1 Shutting off power
5-3-2 Preparation of replacing the UV irradiation lamp
5-3-3 Replacing the UV irradiation lamp
5-3-4 Completion of UV irradiation lamp replacement
F-116
5-3-1. Shutting off power
Procedures for shutting off power
Step No. Do This
1
Press the <System Initial> button to effect system initialization.
- Each axis moves to its origin position.
2
Turn OFF the main switch and then pull out the key.
3
Turn OFF the circuit breaker at the left of the machine. Lock out
the circuit breaker lever with a padlock or the like.
4
Shut off the facility power supply.
Continued in the next section.
F-117
5-3-2. Preparation of replacing the UV irradiation lamp
Procedures for preparation of replacing the UV irradiation lamp
Step No. Do This
(Continued from the previous section)
1
Retrieve the following components from under the cassette stage.
- Inspection plate
- Irradiation shield plate
About removal procedures for the above components;
See the section B-3-7-2, [Replacing the irradiation shield
plate]
2
Lift the front edge of the glass plate and detach it from the pen
cylinder.
Pen cylinder
Glass plate
3
Pull out the glass plate toward you from the inspection workpiece
window.
Glass Plate
Continued in the next section.