00900330-01_UM_ASM-ProcessLens_EN - 第63页
4 Setting up and commissioning 4.2 Infrastructure at the installation location Instruction manual ASM ProcessLens 03/2021 63 4.2.2.3 Mains connection - delivery configuration The main power connection is configured accor…

4 Setting up and commissioning
4.2 Infrastructure at the installation location
62 Instruction manual ASM ProcessLens 03/2021
4.2 Infrastructure at the installation location
4.2.1 Recommendations for foundation quality
The foundation on which the machine is installed must be firm and levelled, as dynamic forces
could cause vibrations when the machine is operated. The degree of vibration depends on the con-
struction of the foundation. The following are suitable provided that the floor loading parameters,
etc., are not exceeded:
●
Reinforced concrete ceiling constructions, e.g. ceilings in production halls
●
Reinforced concrete floor slabs, e.g. concrete floors in production halls without a basement
●
Rooms with double floors, provided that a stable foundation is included in the space between
them. The same setup conditions apply to this intermediate foundation, which can be made
from steel girders or concrete.
4.2.1.1 Maximum ground levelness
The floor underneath the machine may not exceed an incline of 0.63%. This corresponds to an in-
cline of 5mm over a distance of 800 mm.
4.2.1.2 Machine weight and floor loading
The machine weight and floor loading values can be found in section 3.2.1 "Dimensions and ambi-
ent conditions for machine operation" [}53].
4.2.2 Main power supply
WARNING
Some parts of the system carry potentially lethal voltages
The machine is supplied with 1/N/PE 110 V~ to 240 V~, 50/60 Hz mains voltage. This
means that some parts of the system carry potentially lethal voltages - even when switched
off at the main switch. Incorrect handling of the machine can therefore result in death or
severe injury or considerable damage to equipment.
► Always follow the applicable accident prevention and safety regulations (particularly
DIN EN 60204, part 1 or IEC 60204, part 1) and the safety regulations in your own
country.
4.2.2.1 Checking the main power supply
Check whether the power supply complies with the prescribed machine specifications (see table in
section 3.2.4 "Electrical Ratings" [}54]).
NOTICE
Load peaks occur in the power supply
For technical reasons, load peaks occur in the power supply. Please contact your power
company to clarify the mains impedance, if necessary.
4.2.2.2 Power supply cable - specification
The following specifications apply at the customer end to the power supply for the machine:
●
3 x 2.5 mm² (1 x 240 V~) at cable lengths of up to 20 meters between ASM ProcessLens dis-
tribution and mains connection at the customer end. Over 20 meters cable 3 x 4 mm².
The color coding for the wires will depend on the country in which the system is operated.
WARNING
Electrical leads must be clearly labelled
The electrical leads to each individual machine and to the options installed must be clearly
labelled and easily assignable. The regulations of the country in which the machine is oper-
ated apply.

4 Setting up and commissioning
4.2 Infrastructure at the installation location
Instruction manual ASM ProcessLens 03/2021 63
4.2.2.3 Mains connection - delivery configuration
The main power connection is configured according to the power supply of the country concerned.
●
The machine is configured for 110 V AC (optional) to 240V AC voltage.
The machine has a mains power cord AWG 14, 300/500V 3 x 2.5 mm² WITHOUT plug.
Fig.41: Description of wires in the mains power cable
1 brown = (L1): phase 2 blue = (N): neutral conductor
3 green/yellow = (PE): conductor
-or–
●
The machine is configured for 110 V AC (optional) to 240V AC voltage.
The machine has a mains power cord AWG 14, 300/500V 3 x 2.5 mm² WITH C form plug.
Fig.42: Assignment in the C form plug

4 Setting up and commissioning
4.3 Setting up the machine
64 Instruction manual ASM ProcessLens 03/2021
4.3 Setting up the machine
4.3.1 Warning instructions
DANGER
Only ASM SMT Solutions engineers or qualified people are permitted to set up and
commission the machine
► Always follow the applicable accident prevention regulations.
► If you still need to perform assembly work to the underside of the machine, take
appropriate measures to secure the machine first. The forklift must not be used as the
only support.
► Make sure that the inspection head is positioned over the PCB conveyor area so that
you do not restrict your head movement during assembly, thus excluding the risk of in-
jury.
► Two people will be needed to adjust the height of the machine:
► One person to carry out the necessary assembly work and the other person to watch
the raised machine during assembly and ensure that it does not move.
► Wear special safety boots to protect your feet.