SIPLACE D4-D4i 工程师手册_EN - 第142页

Service Work C&P12 Placement Head 4.5.1 Replacing the C&P12 Head (D4) 142 Service Manual SIPLACE D4/D4i Removal Installation See also   6.3.1 Ca librating the C&P Head and C ameras [ ➙ 206] ► Remove the com…

100%1 / 248
Service Work
4.5.1 Replacing the C&P12 Head (D4) C&P12 Placement Head
Service Manual SIPLACE D4/D4i 141
4.4.18.5
4.4.18.5 Extension Controller Board TSP 301E for Dual Conveyors [00370398]
Extension Controller Board TSP 301E for Dual Conveyors [00370398]
Overview
4.5
4.5 C&P12 Placement Head
C&P12 Placement Head
4.5.1
4.5.1 Replacing the C&P12 Head (D4)
Replacing the C&P12 Head (D4)
Overview
Legend
1. Conveyor control TSP 301E
2. Access to conveyor control
3. Transport direction
The extension card for the dual conveyor TSP 301E (1)
is located in the sector distributor 1 (2). The conveyor
control is secured with a screw-off cover.
For terminal assignment details, please refer to the cur-
rent version of the circuit diagram folder.
Legend
1. Illumination controller
2. Vacuum generator
3. 4 x fastening screws
Item number
C&P head DLM3 with 12 segments [03041228-xx]
(C&P12 head)
Service Work
C&P12 Placement Head 4.5.1 Replacing the C&P12 Head (D4)
142 Service Manual SIPLACE D4/D4i
Removal
Installation
See also
6.3.1 Calibrating the C&P Head and Cameras [ ➙ 206]
Remove the compressed air hoses from the pneu-
matic coupling of the pneumatic distributor (1).
Loosen the press-fit connection to the head board (2)
from the C&P head.
Loosen the 4 screws (3) fastening the C&P head.
Carefully pull the C&P head off the parallel pins (4) on
the head mount (5) and remove the head from the
machine.
Carefully move the C&P head towards the head plate
(3).
Make sure that the parallel pins (2) on the head
mount slide into the holes drilled into the back part of
the C&P head.
Carefully push the C&P head towards the head plate
until it lies flat against it.
Fix the C&P head with the 4 screws provided (1).
Connect the compressed air hoses (1) to the pneu-
matic coupling on the pneumatic distributor (2).
Reconnect to the electricity system.
Use the SITEST program to calibrate the C&P head.
1
1
2
Service Work
4.5.2 Removal/Installation of Head Front Part C&P12 Placement Head
Service Manual SIPLACE D4/D4i 143
4.5.2
4.5.2 Removal/Installation of Head Front Part
Removal/Installation of Head Front Part
Parts, equipment and tools
Set of Allen keys
Torx Allen screwdriver TX8 [03080081-xx]
Calibration tool version 3 [03010565-xx]
Assembling instruction for "component sensor" [00193356-xx], if necessary
Removal
NOTICE
Avoid confusing the front and back sections of different heads.
The front and back parts of each specific head belong together.
Make sure that the front and back part of the head always have the same serial number.
Do not confuse these parts with parts from other heads, which have different serial num-
bers.
1. Front part
2. Back part
3. Intermediate distributor (under the cover)
4. 4x fastening screws for the front part of the head
1. Front part
2. Back part
3. Fastening screws for the front part of the head (total
of 4 screws)
4. Compressed air hose for air blast.